background image

7

Model BDF • Belt Drive Duct Fan

®

REPLACEMENT NEOPRENE ISOLATOR(S)

MODEL

FAN SIZE

BDF

80-100

120-150

180-200

BASE MOUNT

R-1 GREEN

R-2 BLACK

R-2 RED

HANGING

40DUR BLACK

50DUR BLACK

50DUR BLACK

REPLACEMENT SPRING ISOLATOR(S)

MODEL

FAN SIZE

BDF

80-90

100-200

150-180

200

BASE MOUNT

FDS-1-70 GREEN

FDS 1-120 GRAY FDS-1-220 BROWN

FDS-1-370 

ORANGE

HANGING

SH-1-70 GREEN

SH-1-125 GRAY

SH-1-245 BROWN SH-1-370 ORANGE

Isolator Parts List

STANDING SUPPORT ISOLATOR

HANGING SUPPORT ISOLATOR

No. Qty.

Description

BDF-80 thru 150

BDF-180 thru 200 No. Qty.

Description

BDF-80 thru 150

BDF-180 thru 200

1

8 Cadium plated 

hex head bolts

3/8 in. - 16 x 1 in.

3/8 in. - 16 x 1 

1/4 in.

1

8 Cadium plated hex 

head bolts

3/8 in. - 16 x 1 in.

3/8 in. - 16 x 1 1/4 

in.

2

8 Cadium plated 

hex nuts

3/8 in. - 16

3/8 in. - 16

2 16 Cadium plated hex 

nuts

3/8 in. - 16

3/8 in. - 16

3

4 Cadium plated 

hex head bolts

5/16 in. - 18 x 1 in. 3/8 in. - 16 x 1 in.

3

4 St. mount bracket 

w/1 - 1/4 in hole

3/16 in.

1/4 in.

4

8

St. mount bracket 

w/2 - 7/16 in. 

holes

3/16 in.

1/4 in.

4

4 St. mount bracket 

w/2 - 7/16 in. holes 3/16 in.

1/4 in.

5 20 Cadium plated 

washer

7/8 in. O.D x 3/8 in. 

I.D. x 1/16 in.

7/8 in. O.D x 3/8 in. 

I.D. x 1/16 in.

5 24 Cadium plated 

washer

7/8 in. O.D x 3/8 in. 

I.D. x 1/16 in.

7/8 in. O.D x 3/8 in. 

I.D. x 1/16 in.

6 12 Cadium plated 

lock washer

3/8 in.

3/8 in.

6 12 Cadium plated lock 

washer

3/8 in.

3/8 in.

7

4 Cadium plated 

washer

1-3/8 in. O.D x 9/16 

in. I.D. x 3/32 in.

1-3/8 in. O.D x 9/16 

in. I.D. x 3/32 in.

7 12 Cadium plated 

washer

1-3/8 in. O.D x 9/16 

in. I.D. x 3/32 in.

1-3/8 in. O.D x 9/16 

in. I.D. x 3/32 in.

8

4 Neoprene or 

Spring Isolator

Reference appropriate table below for 

replacement Isolator(s)

8

4 Neoprene or Spring 

Isolator

Reference appropriate table below for 

replacement Isolator(s)

Isolator I.D.-BVI

Hanging Isolator

Isolator

I.D.-BSI

Base Isolator

7

5

6

Base fastener

  by installer

5

Unit

side panel

7

5

Unit

Side

Panel

2

3

2

5

5

2

NOTE:

Top bracket is reversible

for mounting unit 90

o

from indicated.

(SQ & BSQ only)

2

6

5

5

4

1

5

4

3

6

8

2

6

1

4

6

5

7

8

7

5

6

1

5

2

1

Isolator I.D.-BVI

Hanging Isolator

Isolator

I.D.-BSI

Base Isolator

7

5

6

Base fastener

  by installer

5

Unit

side panel

7

5

Unit

Side

Panel

2

3

2

5

5

2

NOTE:

Top bracket is reversible

for mounting unit 90

o

from indicated.

(SQ & BSQ only)

2

6

5

5

4

1

5

4

3

6

8

2

6

1

4

6

5

7

8

7

5

6

1

5

2

1

Isolator I.D.-BVI

Hanging Isolator

Isolator

I.D.-BSI

Base Isolator

7

5

6

Base fastener

  by installer

5

Unit

side panel

7

5

Unit

Side

Panel

2

3

2

5

5

2

NOTE:

Top bracket is reversible

for mounting unit 90

o

from indicated.

(SQ & BSQ only)

2

6

5

5

4

1

5

4

3

6

8

2

6

1

4

6

5

7

8

7

5

6

1

5

2

1

Isolator I.D.-BVI

Hanging Isolator

Isolator

I.D.-BSI

Base Isolator

7

5

6

Base fastener

  by installer

5

Unit

side panel

7

5

Unit

Side

Panel

2

3

2

5

5

2

NOTE:

Top bracket is reversible

for mounting unit 90

o

from indicated.

(SQ & BSQ only)

2

6

5

5

4

1

5

4

3

6

8

2

6

1

4

6

5

7

8

7

5

6

1

5

2

1

Summary of Contents for Belt Drive Duct Fan BDF

Page 1: ...ional engineer before moving forward 1 Follow all local electrical and safety codes as well as the National Electrical Code NEC and the National Fire Protection Agency NFPA where applicable Follow the Canadian Electric Code CEC in Canada 2 The rotation of the wheel is critical It must be free to rotate without striking or rubbing any stationary objects 3 Motor must be securely and adequately groun...

Page 2: ...atures should be evenly maintained between 30 to 110 F 1 to 43 C wide temperature swings may cause condensation and sweating of metal parts All accessories must be stored indoors in a clean dry atmosphere Remove any accumulations of dirt water ice or snow and wipe dry before moving to indoor storage To avoid sweating of metal parts allow cold parts to reach room temperature To dry parts and packag...

Page 3: ...oged Open Drip Proof motor Chart 2 Filter Option Dimensions BDF Size K B C D E F G H Filter Size Filter Quantity 80 493 4 1264 181 2 470 157 8 403 153 16 386 1211 16 322 93 4 248 87 8 225 1 25 16 x 20 406 x 508 2 90 547 8 1394 211 4 540 183 4 476 181 4 464 157 8 403 121 4 311 101 2 267 1 25 20 x 25 508 x 635 2 100 517 8 1318 223 4 578 203 4 527 193 4 502 177 8 454 133 4 349 117 8 302 1 25 20 x 20 ...

Page 4: ...rtain all connectors are tight and that all washers are in 5 If adjustments are made it is very important to check the pulleys for proper alignment Misaligned pulleys lead to excessive belt wear vibration noise and power loss See figure 5 6 For all BDF Fans Belt tension can be adjusted by loosening four fasteners marked R figure 6 on the drive frame The motor plate slides on the slotted adjusting ...

Page 5: ...emoving dust buildup on motor housing ensures proper motor cooling Greasing of motors is only intended when fittings are provided Many fractional horsepower motors are permanently lubricated and should not be lubricated after installation Motors supplied with grease fittings should be greased in accordance with manufacturers recommendations Where motor temperatures do not exceed 104 F 40 C the gre...

Page 6: ...s per day in clean relatively dry atmosphere 12 to 18 Infrequent operation or light duty in clean atmosphere Table 2 Grease Manufacturers Manufacturer Grease NLGI 2 U S Electric Motors Grease No 83343 Chevron U S A Inc Chevron SRI Grease 2 Mobil Oil Corporation Mobilith Mobil 532 Texaco Inc Premium BRB 2 Texaco Multifak 2 Amoco Oil Co Rykon Premium 2 Exxon Unirex N2 Shell B Shell Alvania 2 4 Once ...

Page 7: ... 8 in 3 8 in 6 12 Cadium plated lock washer 3 8 in 3 8 in 7 4 Cadium plated washer 1 3 8 in O D x 9 16 in I D x 3 32 in 1 3 8 in O D x 9 16 in I D x 3 32 in 7 12 Cadium plated washer 1 3 8 in O D x 9 16 in I D x 3 32 in 1 3 8 in O D x 9 16 in I D x 3 32 in 8 4 Neoprene or Spring Isolator Reference appropriate table below for replacement Isolator s 8 4 Neoprene or Spring Isolator Reference appropri...

Page 8: ...additional information describing the equipment fan performance available accessories and specification data Phone 715 359 6171 Fax 715 355 2399 E mail gfcinfo greenheck com Website www greenheck com Warranty AMCA Publication 410 96 Safety Practices for Users and Installers of Industrial and Commercial Fans provides additional safety information This publication can be obtained from AMCA Internati...

Reviews: