Greenheck ATI Brochure & Specs Download Page 3

Page Header

3

Model GPI Standard 

Construction Features

INSUlATION

 - Ridged fiberglass insulation is standard on 

all GPI curbs. The insulation is securely attached at both the 
top and bottom with an insulation tray so it will not have any 
exposed ends. Three pound density insulation is available in 
1, 1

1

2

, and 2-inch thicknesses.

lAP JOINTS

 -  Wood 

nailers attached to GPI 
curbs consist of notched 
and lapped joints to ensure 
strength and durability.

FORMED BODY CURB

 -  

Curbs are perfectly formed 
on three sides and have only 
one welded seam to ensure a 
strong square curb.

CONSTRUCTION

 -  

Curb sizes under 
50 inches square are 
18 gauge galvanized 
steel or 0.064 aluminum. 
Curb sizes 50 inches 
square and greater are 
16 gauge galvanized 
steel or 0.080 aluminum.

OPTIONAl DAMPER TRAY

 - 

Designed to hold a standard 
Greenheck damper. The design 
includes flanges, which allow the 
damper to be placed in the tray 
and fastened.

OPTIONAl COATINGS

 - 

A wide variety of coatings and 
colors are available:
Decorative coatings are available in 
sixteen standard colors.
Protective coatings are available 
in five electrostatically applied 
powders providing a selection for 
most environments.

All coatings and relative resistance 
charts can be found in Greenheck’s 
Product Application Guide for 
Performance Coatings for Ventilation 
Products.

OPTIONAl SECURITY BARS

 - 

Model GPI with security bars is 
available up to 50 by 
92 inches to prevent 
unlawful entry. The bars 
consist of 1/2-inch diameter 
A-36 mild steel, welded 
6 inches apart from one 
another and are powder 
coated.

OPTIONAl CURB SEAl

 - This rubber seal between 

the fan and the curb cap is available to ensure 
proper performance of the fan. The seal also helps 
prevent insects and moisture from entering and 
reduces vibration transmission in the ductwork.

OPTIONAl lINER (Double Shell)

 - Available for 

installations where it is not desirable for insulation 
to be exposed to the airstream.

Summary of Contents for ATI

Page 1: ...Roof Curbs Extensions and Equipment Supports August 2008 ...

Page 2: ...dictating manufacturing time Your custom product configuration can be manufactured in one three five or ten days then shipped to your job site Leading Edge Technical Support When you need extensive product information look no further Greenheck products are supported by the industry s best product literature including catalogs Installation Operation and Maintenance Manuals IOM electronic media Comp...

Page 3: ... allow the damper to be placed in the tray and fastened Optional Coatings A wide variety of coatings and colors are available Decorative coatings are available in sixteen standard colors Protective coatings are available in five electrostatically applied powders providing a selection for most environments All coatings and relative resistance charts can be found in Greenheck s Product Application G...

Page 4: ... flashing flange then roofed and flashed to the top of the wood nailer for weather tightness For pitched or ridged applications use models GPIP GPIR GPFP or GPFR Model GPS consists of a fully welded body and 1 inch insulation Model GPS is available in heights of 8 to 18 inches Model GPR with raised cant This curb is designed for use on flat insulated roof decks It is mounted directly to the deck s...

Page 5: ...CE The VCE vented curb extension is typically used in kitchen applications where the vents allow hot air and gases to escape between the ductwork and the roof curb Designed for use with an 8 inch high roof curb and Greenheck fan models CUBE CUE or USGF to provide the required 40 inch minimum discharge height above the roof line per NFPA 96 Model VCE consists of galvanized steel or welded aluminum ...

Page 6: ...or roof decks and consist of continuous welded seams Model ATI for use on flat non insulated roofs ATIP for pitched roofs and ATIR for ridge double pitched roofs They are mounted directly to the roof deck with a 2 inch flashing flange before the insulation is applied then roofed and flashed to the top of the wood nailer for weather tightness Model ATE Sound attenuating curb extensions are designed...

Page 7: ...hes larger than the curb AD dimensions Minimum adapted amount 11 2 inches Maximum adapted amount 10 inches Adapter Fan curb cap is smaller than existing curb A B 2 1 2 in 1 500 Fan Curb Fan Curb Curb Adapt Down A 2 1 2 in Curb Cap W L AD Curb Cap W L 1 2 in Adapted Curb Cap W L Reducer Fan curb cap is larger than existing curb GPF GPI FLANGED CURB WOOD NAILER CURB 1 in 1 in Dimensional Data Model ...

Page 8: ...08 RG Copyright 2008 Greenheck Fan Corp Typical Installation Greenheck s straight sided roof curbs are designed for general exhaust or supply applications General Flashed Roof Installation 1 Remove roofing material where roof penetration is to be made and provide a 10 inch wide clearance around perimeter of hole in roof 2 Apply roofing cement around roof opening 3 Place and center roof curb over h...