Coverage

Minor Motion, Ultrasonic

Major Motion, Ultrasonic

Maximum coverage area may

vary somewhat according to room

shape and the presence of obstacles.

The NEMA WD 7 Guide and robotic

method were utilized to verify

coverage patterns.

Minor Motion, IR

Major Motion, IR

8.5 ft

(2.59 m)

5 ft

(1.52 m)

10 ft

(3.05 m)

15 ft

(4.57 m)

23 ft

(7.01 m)

0

9 ft

(2.74 m)

9 ft

(2.74 m)

0

12 ft

(3.65 m)

12 ft

(3.65 m)

20 ft

(6.096m)

20 ft

(6.096m)

Installation Instructions

Model # OAC-DT-0501
Model # OAC-DT-0501-R
Model # OAC-DT-1000
Model # OAC-DT-1000-R
Model # OAC-DT-2000
Model # OAC-DT-2000-R

Dual Technology Ceiling Mounted Low

Voltage Occupancy Sensor

• Read all instructions on both sides of this sheet first
• Install in accordance with ALL local codes
• For indoor use only

• For Use with Greengate Switchpacks & Systems Only
• Do not run any Greengate Low Voltage Wiring in the

same conduit as power conductors

General Information

Cooper Controls
203 Cooper Circle, Peachtree City, GA 30269
800-553-3879
www.coopercontrol.com 

Power Requirements:

Input:

• 10-30 VDC from Greengate Switchpack or Greengate

system. Maximum current needed is 25mA per sensor

Output:

•  Open collector output to switch up to ten  

Greengate Switchpacks. 

•  BAS with Isolated Form C Relay (-R model)
•  Isolated Form C Relay Ratings: 1A 30 VDC/VAC

Operating Environment:

• Temperature: 32° F – 104° F (0° C – 40° C)
• Relative Humidity: up to 90% non-condensing

Specifications

Description

Ultrasonic
Activated

The OAC-DT Ceiling Mount Low Voltage Occupancy Sensor is a Passive Infrared (PIR) and Ultrasonic (US) motion

sensing lighting control, used for energy savings and convenience. PIR is used to turn the lights ON and then either
technology is used to keep the lights ON. When motion is detected, the blue wire is electronically connected to the
red wire, energizing the relay in the switchpack to turn on the load. If vacancy is detected, the blue wire is discon-
nected from the red, causing the relay to open turning OFF the load. The red lead is 10-30 VDC supply, the black
lead is common, and the blue is the relay control.

The sensor includes self-adaptive technology that continually adjusts to conditions by adjusting sensitivity and Time
Delay in real-time.

Location

The maximum coverage area may vary somewhat according to room shape and the presence of obstacles. Decrease

total coverage area by 15% for “soft” rooms (for example, heavy draperies or heavy carpeting). The sensor must have a
clear view of the area to be controlled. The sensor will not “see” through glass. Mounting height should not exceed 12
feet. Optimum mounting height is 8 to 10 feet. Mount the sensor so the grilles face the open portion of the room and are
not  facing  a  nearby  wall,  door,  window,  or  other  obstructing  object.  Avoid  pointing  into  hallways.  Mounting  at  fixture
height is most effective. *To prevent false activation, the sensor should be mounted away from the air supply duct a min-
imum of 4 to 6 feet.

Installation

The OAC-DT sensor can be mounted to the ceiling, junction box, or round fixture with raceway.

Wiring

CAUTION: Before installing or performing any service on a Greengate system, the power MUST be turned OFF at
the branch circuit breaker. According to NEC 240-83(d), if the branch circuit breaker is used as the main switch
for a fluorescent lighting circuit, the circuit breaker should be marked “SWD”. All installations should be in com-
pliance with the National Electric Code and all state and local codes.  

NOTE REGARDING COMPACT FLUORESCENT LAMPS: The life of some compact fluorescent lamps (CFLs) is shortened

by frequent automatic or manual switching. Check with CFL and ballast manufacturer to determine the effects of cycling.

1. Make sure power is turned OFF at the branch circuit breaker.
2. Wire units as shown in wiring diagrams per applicable voltage requirements. (Use twist-on wire connectors 

for all connections) CAP ALL UNUSED WIRE LEADS. 

3. Mount unit to ceiling, junction box, or round fixture with raceway.
4. Turn power back ON at the branch circuit breaker and wait 2 minutes for the unit to stabilize.
5. Make necessary adjustments. (See Checkout and Adjustments section)

OAC-STEM Threaded Rod

(sold separately)

Coverage

OAC-DT-1000-R Coverage Diagram

OAC-DT-0501-R Coverage Diagram

OAC-DT-2000-R Coverage Diagram

Load 1

Blue

Neutral

Hot

**Use black lead for 120 VAC 

Use orange lead for 277 VAC  
Cap unused lead.

Line

**

H

o

t

W

h

it

e

B

lu

e

SWITCH-

PACK

 Black

 Blue

 Brown

 Yellow
 Purple

 Gray
 Orange

 Red

 White/Brown

Load 2

Blue

Neutral

Hot

**Use black lead for 120 VAC 

Use orange lead for 277 VAC  
Cap unused lead.

Line

**

H

o

t

W

h

it

e

B

lu

e

SWITCH-

PACK

 Black (Common)

Blue (Control)

 Red (15 VDC)

 Black (Common)

Blue (Control)

 Red (15 VDC)

Model GMDS - Load 2

(Normally Open

Momentary Switch)

Model GMDS - Load 1

(Normally Open

Momentary Switch)

Manual Mode Operation:

Switches are required to 
turn corresponding loads ON.  
Lights turn OFF when sensor 
times out or with the 
switch.

Automatic Mode Operation:

Sensor turns ON both 
switchpacks. Switches can 

be used to turn lights ON 
or OFF.

If daylight sensor is 
enabled and light level is 
above setpoint, switchpack 
connected to yellow lead 

will not turn ON.

 
Recommended Wire:

18-3 AWG Stranded Wire 
non/shielded. 

Manual or Automatic-On Control of
Two Standard Switchpacks

Load

Blue

Neutral

Hot

**Use black lead for 120 VAC 

Use orange lead for 277 VAC  
Cap unused lead.

Line

**

H

o

t

W

h

it

e

B

lu

e

SWITCH-

PACK

To additional sensors 

Maximum of 5 sensors 
per switchpack

 Black

 Blue

 Red

 Black (Common)

Blue (Control)

 Red (15 VDC)

To additional switchpacks 

Maximum of 10 switchpacks 
per sensor

One Sensor, One Switchpack

SENSOR WIRE LEAD LEGEND

Black      (Common)

Red 

  (10-30 VDC)

Blue

  (Control - Occupancy)

Yellow

  (Control - Occupancy and Daylight)

Brown

  (Switch-Blue  Lead Control)

Brown/White (Switch-Yellow Lead Control)
Sensor's Isolated Relay

Orange   (Normally Open)

Gray 

  (Common)

Purple

  (Normally Closed)

30 ft

0.762 m

30 ft

0.762 m

15 ft

0.381 m

30 ft

0.762 m

OAC-DT-1000 & OAC-DT-2000

OAC-DT-0501 