background image

Model Number: J62-Y

PowerBreaker J62-Y is a two pole in-line

portable RCD, designed for use in commercial

and industrial environments where rough 

handling is expected. The water resistant 

casing of the unit is rated at IP65 (IEC 61540).

This unit should be installed to current  IET

wiring regulations if in doubt consult 

a qualified electrician.

This product should be wired with 1.5mm2

3 core flexible cable (BS6500).  Connect cable

to the input and output terminals, ensuring

that the following is observed.
• Live/Brown to Brown wire terminal

• Neutral/Blue to Blue wire terminal

• Earth Green/Yellow to Green/Yellow 

Terminal

Ensure that there are no loose strands of wire.

To ensure the IP rating, terminals and cover

should be sealed with the supplied sealant.

• When fitting plugs, sockets or connectors 

follow the accessory manufacturer’s 

instructions ensuring that the live, neutral 

and earth (if any) cores are connected 

correctly and the outer covering of the 

cable is firmly secured.

• The plug on the appliance should be 

fused in accordance with the appliance 

manufacturer’s instructions.

• To maintain the IP65 weather proof 

rating of the device, plugs, sockets and 

connectors of an equivalent rating must 

be used

.

Please carry out the simple test procedure

prior to each use.

• Insert plug into power socket outlet.

• Press and release reset button - 

the red indicator should appear in the 

window.

• Press the test button - the red indicator 

should disappear.            

This means the RCD has tripped 

successfully, cutting off the power from 

the RCD.

• Now press and release the reset button 

again, the unit is ready for use.

If the red indicator fails to work as described

above, do not use.

IMPORTANT FOR YOUR PROTECTION

• Electricity is dangerous and an RCD 

must not be used as a substitute for 

normal precautionary measures. 

• Always unplug from mains supply before 

any inspection or repair to equipment.

• Do not allow children to tamper with 

electrical devices.

• Should your PowerBreaker repeatedly 

trip with an appliance connected, or fail 

to trip when tested, seek advice 

immediately from a competent electrician

or return to place of purchase.

• This device will protect against live and 

neutral faults to earth. It will not protect 

against electric shock due to contact with

both conductors, short circuits between 

live and neutral, or a fault in the wiring 

supplying this device