Green GPM-303 Quick Manual Download Page 2

SET

 Press 

 PARAMETER SELECTION

before Power ON for  

 OPERATION PROCEDURE :

>

Press

LED BLINKS

Blinking display
increments 

  Returns after 1Sec.

     and release

Press 

for 3sec

Press

SET

Power ON 

to shift blinking
position

SET

Relay and Count is reset

     Counting

Up count

COUNTING =
 SET VALUE

  Pulse input

No

Yes

(Relay ON)

Reset Type
 If 

No

Yes

Relay Reset 

after Output Time

See Note

Press

SET

OPERATION LEVEL

OR

Scaled value will displayed in PV display.

Actual value will displayed in PV display.

>

This can be changed by pressing         in Operation level

Press

>

PV DISPLAY

 SET VALUE SELECTION

   SET POINT DISPLAY

Count and relay can be reset in
the following ways and the offset
 value will automatically loaded

     1.By giving external 
        reset signal

     2.By pressing Set key
        for 3Sec in operation
        level.(Display enters
        set value selection
        screen)

NOTE:

F

OPERATION LEVEL

Press

>

If

Press

>

(or)

Choose Relay Reset type

(or)

Press

>

Press

>

Press

>

Press

>

Press

SET

Press

SET

Press

SET

Press

>

If

Press

>

Press

>

Press

SET

Press

SET

Press

SET

 PARAMETER SELECTION

HIGH

LOW   

PNP

NPN   

AUTO

MANUAL   

Auto

 : As soon as count reaches Set Value,the present value display 

               returns to the reset status.

               The output is held ON until Output Time is complete

Manual

 : The present value continues to increment 

               and the output is held ON until reset.

OPERATION AFTER COUNT COMPLETION

Input

 Frequency

Input

 Input

Input

 Reset

Input

 Output Time

Scaling

Offset

Decimal

Press

>

Press

>

DECIMAL POSITION

Selected the decimal point position
is shown in the PV display 

F

Press

>

Press

>

Press

>

>

Press

>

After reset this value will load

VALUE SETTING

SIGN SETTING

>

Press

Press

>

VALUE SETTING

NOTE: Count  X Scale = PV 

Press

>

DECIMAL SETTING

Choose           for input
frequency < 30 Hz

Choose            for input
frequency < 5 KHz

(or)

Choose          for
PNP type sensor

Choose          for
NPN type sensor

HOLD

RESET   

Press

>

   Set Value     :  2000 counts

   Output Time :  10 Sec

 Relay turns ON when 2000 counts is reached.

 After 10Sec relay turns OFF

EXAMPLE:

 

F

(or)

Choose                for resetting output time and 
relay status during power failure

F

IF AUTO RESET MODE IS SET

Choose             for output time and relay status
 retention during power failure.

Sec

>

>

Set the time using

and

Timer Memory

Press

>

Press

SET

Press

SET

Press

>