Section 5 Battery Maintenance
(1) The surface of the battery, pole and connecting bolt, connecting line
should keep clean and dry. If the electrolyte splashed on body please use
cotton wipe clean, then wash and dry, ensure no water enters into battery.
(2) Battery connection must be kept in good. Always check the battery
connection fastening and nut loosening, lest cause spark in driving to ablate
electrode.
(3) Don’t place any conductive materials on battery, can not connect the
battery positive and negative poles directly to avoid cause a short circuit and
damage the battery.
(4) After battery discharge(regardless of vehicle ranges and driving time),
must be charged timely, charging tie should not exceed 24 hours delay.
(5) Because the electrolyte water electrolysis and evaporation will cause the
density increases and the level lower in using, so should always check.
In the charging of the battery terminal, please adjust electrolyte density to
1.28 0.0025(25
℃
) by 1.400 density dilute sulfuric acid specified for lead acid
battery, make the liquid height same as max. Level, continue to charge 0.5-1
hours after adjustment, so that the internal consistency.
Note: In order to ensure longer life of your battery, please go to service
center to fill battery electrolyte.
(6) During charging, please put the vehicle at airy place, and open the
battery cover, after charging, tighten liquid injection cover, ensuring smooth
gas. Don’t in charge at smoking or stack flammable goods place.
(7) When close to lead-acid battery service life, battery capacity will declined
rapidly, must replace the new battery. The new battery must be the same
with the original vehicle battery manufacturers and same model. And the
similar voltage battery cell as a group(full charge, the difference between the
highest voltage shall not exceed 1.1V).
Note: please go to service center to replace the battery, strictly
prohibited to replace battery by yourself, otherwise it will cause electrical
parts burn out, or even more serious safety accidents.