Green Leaf Workhorse Sprayers 3PT Series Assembly / Operation Instructions / Parts Download Page 9

Installation and Operation Precautions

 

 

y

The pump is equipped with a pressure sensing demand switch that controls the maximum 

operating pressure.

 

y

In addition, never subject the pump to pressures above factory set/max pressure rating.

 

y

As long as there is inlet water pressure, the pump will not stop forward flow of water even if the 

motor is turned off. Be sure the system has positive means of shutting off water supply.

 

y

Do not operate pump in an explosive environment. Arcing from the motor brushes, switch or 

excessive heat from an improperly cycled motor may cause an explosion.

 

y

Do not locate the pump motor near low temperature plastics or combustible material. The 

surface temperature of the motor may exceed 180°F (82°C).

 

y

Do not pump gasoline or other flammable liquids. Pump head materials are designed for use 

with water only. Do not use with petroleum products.

 

y

Do not assume fluid compatibility. If the fluid is improperly matched to the pumps’ elastomers, 

a leak may occur.

 

y

To prevent electrical shock, disconnect power before initiating any work. In the case of pump 

failure, the motor housing and/or pump fluid may carry high voltage to components normally 

considered safe. Therefore, always consider electrical shock hazard when working with and 

handling electrical equipment. If uncertain, consult an electrician. Electrical wiring should only 

be done by a qualified electrician per local and state electrical codes. 

Servicing —

 

y

Every Year: Check system against operating standards. Flush with clean water and store in 

warm dry place.

 

y

Every 2-3 Years: We recommend replacing the valves and checking against operating 

standards.

Recommendations —

 

 

Electrical: 

 

y

The ProFlo™ series pumps are designed for intermittent duty. Make sure that “OFF” periods are 

sufficient. Consult the factory for particular data and design criteria.

 

y

Be sure power supply used is adequate for the application.

 

y

Pump and motor specifictions are based on an alternator charged battery (13.6 VDC)

 

y

Use sufficient battery supply power. UTV and lawn tractor batteries may affect pump  

performance due to low voltage and amp ratings

 

y

Rapid On/Off Cycling must be limited to no more than 6 times per minute, even 

if the pump is operating in the Continuous Duty zone. Cycling could cause the 

motor to heat beyond the recommended maximum temperature, and reduce the 

operational life of the pump and pressure-sensing switch.

Important return safety instructions - 

When returning your pump for warranty or repair, you must always do the following:

 

y

Contact factory for RMA number. 

 

y

Flush chemical residue from the pump (best done in the field).

 

y

Tag pump with type of chemicals having been sprayed.

 

y

Include complete description of operation problem, such as how pump was used, symptoms of 

malfunction, etc. Since pumps can contain residues of toxic chemicals these steps are  

necessary to protect all the people who handle return shipments, and to help pinpoint the 

reason for the breakdown.

PUMP INFORMATION:

Type 

- 3 chamber diaphragm pump, self priming, 

capable of being run dry

Pressure Control - 

Demand

Liquid Temperature -

 140°F (60°C) Max.

Priming Capabilities -

 10 feet (3 m)

Max Pressure -

 100 PSI (6.9 bar)

Inlet/Outlet Ports - 

3/4" Quick Attach 

Weight - 

5 lbs (2.3 kg) 

MOTOR INFORMATION

Leads - 

14 AWG, 7˝ long with 2-Pin 

Temperature Limits - 

Motor is not equipped 

with thermal protection. For user safety, optimal 
performance, and maximum motor life, the motor 
surface temperature should not exceed 180°F (82°C)

PUMP INFORMATION:

Type

 - 3 chamber diaphragm pump, self priming, 

capable of being run dry

Pressure Control - 

Demand

Liquid Temperature - 

140°F (60°C) Max.

Priming Capabilities - 

8 feet (2.4 m)

Max Pressure -

 200 PSI (14 bar)

Inlet/Outlet Ports - 

3/4” Quick Attach

Weight - 

6 lbs (2.7 kg)

MOTOR INFORMATION

Leads - 

14 AWG, 7˝ long with 2-Pin 

Temperature Limits - 

Motor is not equipped 

with thermal protection. For user safety, optimal 
performance, and maximum motor life, the motor 
surface temperature should not exceed 180°F (82°C)

PUMP INFORMATION:

Type -

 5 chamber diaphragm pump, self priming, 

capable of being run dry

Pressure Control - 

Demand

Liquid Temperature - 

140°F (60°C) Max.

Priming Capabilities - 

14 feet (4 m)

Max Pressure Capabilities - 

150 PSI (10 bar)

Inlet/Outlet Ports - 

3/4” Quick Attach 

Weight - 

8 lbs (3.62 kg)

MOTOR INFORMATION

Leads - 

14 AWG, 7˝ long with 2-Pin 

Temperature Limits - 

Motor is not equipped 

with thermal protection. For user safety, optimal 
performance, and maximum motor life, the motor 
surface temperature should not exceed 180°F (82°C)

12 Volt DC Motor-Driven Diaphragm Pumps

3300 Series: 2.2 GPM

3200 Series: 3.2-4.0 GPM

5500 Series: 4.0-5.3GPM

Remco Industries - 4605 County Rd 82 SE - Alexandria, MN - 763-253-4740 - www.remcoindustries.com

Summary of Contents for Workhorse Sprayers 3PT Series

Page 1: ...f purchase against manufacture or workmanship defects for personal or homeowner usage with proof of purchase Work horse products are warranted for 90 days for commercial users Any unauthorized modific...

Page 2: ...ases Be sure to read the chemical label carefully Determining the proper speed of the tractor can be done by marking off 100 200 and 300 feet The speed chart indicates the number of seconds it takes t...

Page 3: ...2 4 Front Support 640400 1 5 Boom Bracket 640411 2 6 Lower Link Pin 640425 2 7 5 16 Plain Washer 640422 4 8 5 16 Hex Nut 600172 10 9 5 16 x 1 25 Bolt 640421 6 10 5 16 x 3 75 Bolt 640424 4 11 A 10 10...

Page 4: ...lastic Hose Wrap Wand Clip Screws 2 2 GPM Lead Wire Assy Drain Cap Assembly Deluxe Wand with 25ft Hose 4 0 5 0 GPM Lead Wire Assy Assembly Instructions 2 0 Insert Lead Wire Assembly into plug at rear...

Page 5: ...ackets to each end of the 45 Center Boom Section using 5 16 x 2 Pan Head Screws as shown 1 2 Install the Boom Hinge Bolts 5 16 x 2 Pan Head Screws Throught the Boom Center Brackets and the Boom End Br...

Page 6: ...ket 2 3 Attach Bonnet Cap to Nozzle Body fittting 2 4 Install Hose Assembly onto inline valve on the Pump Manifold DESCRIPTION PART NUMBER 7 Nozzle 5 Nozzle ITEM 5 8 Hose Clamp 600120 14 10 1 Nozzle B...

Page 7: ...y be installed while the Boomless Manifold is not installed on the Boomless Bracket and is used to secure the hose to the Manifold 1 2 Install Boomless Manifold Assembly onto the Boomless Bracket usin...

Page 8: ...bly if equipped The Lever adjusts the system pressure by relieving liquid back to the tank Adjusting this lever will increase or decrease pressure to both the spray wand and the spray boom The lever t...

Page 9: ...e operationallifeofthepumpandpressure sensingswitch Importantreturnsafetyinstructions Whenreturningyourpumpforwarrantyorrepair youmustalwaysdothefollowing y ContactfactoryforRMAnumber y Flushchemicalr...

Page 10: ...I check Check all electrical connections Ensure switch is in the on position Check in line fuse and or fuse in car adapter end Ensure correct voltage 10 12 13 volt Low flow or no flow at all what shou...

Reviews: