Pressing the encoder will open the setup menu of the Green-GO Bridge X. Once in the 
menu, the encoder will allow you to navigate through the menu and set a parameter. 
Pushing the encoder will confirm your selection.  

 

 

The setup menu offers a range of different settings to modify your device. 
The menu sections and their supplementary options are described in detail below. 
 

Setting up a bridge port 

 
Here you can set-up all Bridge X ports. 

 

Port x : yyyy

 

 

Mode: Off  

à

 

This Bridge port is switched off 

 

Mode: Group Bridge

 

à

Set this port to Group Bridge mode. In group bridge mode 

you can transfer one group of your local Green-GO network to another 
Green-GO network. Note that this other network does not have to have 
the same configuration and the Group name can be different on both 
sides.  

 

Mode : User access  

à

Set this port to User Access. in User access mode you can 

transfer A single user from your local Green-GO network to a remote 
Green-GO network or Green-GO device. This User is a Remote member 
of your local Green-GO network and shares the Config. 

 

 

 

 

Setup menu navigation

 

Setup menu overview

 

Summary of Contents for Bridge X

Page 1: ...Bridge X Quick Start Guide...

Page 2: ...Device or network anywhere in the world It is able to route up to 4 Users or Groups to a remote location 4 bridge ports available Bridge mode to allow a remote connection to your network Remote mode t...

Page 3: ...p a bridge port Here you can set up all Bridge X ports Port x yyyy Mode Off This Bridge port is switched off Mode Group Bridge Set this port to Group Bridge mode In group bridge mode you can transfer...

Page 4: ...p to another port Enabling this will allow you to connect the same group to 3 or more locations without the need to make a bridge connection between all locations Don t route An incoming Group can t b...

Page 5: ...on both sides of the connection A different and free port needs to be used for each connection SndBuf Set up the size of the audio packages being sent out from this port A connection with high jitter...

Page 6: ...ter in latency needs a larger Buffer Save Save all changes made on this port connection Cancel Discard all changes made on this port connection Configuration cloning All devices in the local Green GO...

Page 7: ...ave this menu Backlight Set the time out of the display Always on or a range from 10 seconds through 4 hours Display Set the Intensity of the display Device information Info Shows general information...

Page 8: ...nstructions Do not insert any objects through the ventilation slots of the unit as these could come in contact with live parts or could cause short circuits This could cause electric shock and or fire...

Page 9: ...idge X Which refer to this declaration are manufactured in the Netherlands and complies with the following product specifications and harmonized standards Safety LVD Low Voltage Directive 2014 35 EU E...

Reviews: