Green Brook KingShield TXPIR120 Installation Instructions Download Page 2

Daylight Control

The daylight control adjusts the level of

daylight the infrared detector becomes

activated at, so that it can detect. Turn

the control clockwise to decrease the

lighting value so the light will come on

later in the evening. Turn the control

anti-clockwise to increase the lighting

value so the light will come on earlier in

the evening.

TESTING

By setting the time and daylight control

to fully anti-clockwise a daylight walk-by

test can be performed to check operation

in daylight after the initial installation.

Field of Detection

The field of detection of the infrared

lamp can be adjusted

30

°

vertically and

30

°

horizontally.

The horizontal

120

°

detection

range can be

reduced or

expanded, see

Fig.

4

&

5

, to

reduce any false

detections caused

by movements

from neighbour-

ing

grounds.

The best detec-

tion

is obtained by

approaching

the field of

detection

perpendicular

to its axis. See

Fig.

6.

If the field

of detection is

approached

in the direction

of its axis, the

infrared detector

will, in some

cases, respond

later. See Fig.

7

.

TROUBLE SHOOTING

• On installation please do not fix the

lamp under a roof or under trees, as

the lamp can light up during daylight

hours.

• If your lamp suddenly stops working,

the bulb or fuse could be defective or

there may have been a failure in the

Is

s

u

e

n

o

:

7

0

3

2

9

7

WEST ROAD . HARLOW
ESSEX . CM

20 2

BG . UK

s a l e s @ g r e e n b r o o k . c o . u k

W W W. G R E E N B R O O K . C O . U K

Fig.

4

Fig.

6

Fig.

7

Fig.

5

Power Source:

220

-

240

V AC,

50

Hz

Max Lighting Load:

120

W class C Xenon Tube

Dectection Angle:

120

degrees (fan shaped)

Detection Range:-

12

M

Time Delay:

From

9

secs to

10

mins

(adjustable)

Light Sensivity:-

30 Lux

(adjustable)

Power Cord:

H05RN-F 3G 1.0

mm

2

Glass:

133 x 92 x 4

mm

TECHNICAL INFORMATION

electrical circuit. Please contact a

qualified electrician.

• Your lamp may not work satisfactorily

if it is placed in such a way that the

field of detection is not walked

through. Please ensure the detection

area is tested every now and again.

• If the temperature difference between

the object to be detected and the

surrounding area is too small (in the

summer for example) then your lamp

will react later. The range of detection

is then

10

metres instead of the

normal

12

metres for example.

Please keep these instructions

for future reference.