Green Brook KingShield TXPIR120 Installation Instructions Download Page 1

Installation Instructions

For Xenon Floodlights with PIR

Model Ref: TXPIR

120

(Black)

& TXPIR

120

W (White)

This unit should be installed by a competent

person in accordance with the current IEE

Wiring Regulations. If in doubt consult

a qualified electrician.

INSTALLER - PLEASE READ THIS

INSTRUCTION MANUAL

BEFORE INSTALLING THE UNIT

This floodlight is provided with an

infrared detector. The detector senses

‘warmth movement’ in the surrounding

area and when it is dark. When movement

is detected the lamp will come on. This

fitting has no manual override.

INSTALLATION

Switch the power off before installation

to prevent electric shock.

NOTE

1

.

On installation try not to install light

fitting close to a vent such as a vent

from a boiler or tumble dryer as hot

air movement can cause the lamp to

switch on when it is not required to.

NOTE

2

.

Passing cars (warm engines) and

nearby trees and bushes can cause

your lamp to switch on, due to a

sudden change in temperature and

gusts of wind. Please bear this in

mind when deciding on where to

install your light.

NOTE

3

.

Do not mount the fitting in the ceiling.

NOTE

4

.

Please ensure the distance between

the front glass of the lamp and the

surface area the lamp is lighting is at

least

1

metre apart.

1

. The lamp fitting can be installed using

the three holes on the mounting

bracket. The bracket should be

horizontally fixed. See Fig.

2

.

2

. Loosen the supporter bolts to adjust

the installation angle of the lamp in

accordance with the lighting direction

needed. The lighting direction cannot

be adjusted downwards more than

45

°

,

see Fig.

2

.

Fig.

1

Fig.

3

ELECTRICAL WIRING

Open the terminal box cover and

unscrew the inlet gland and remove

the sealing ring. Thread the power

cable through the inlet gland and the

sealing ring.

Live = Brown/Red

Neutral = Blue/Black

Earth = Green and Yellow

Insert the wire ends into the terminal

block and then tighten them. Replace

the box cover, screw in the inlet

gland together with the sealing ring.

INSTALLING THE LAMP TUBE

1

. Unscrew the bolt and open the glass

holder. Fit the tube into the tube

socket. Keep the waterproof rubber

pad in its original position and close

the glass holder with the bolt.

2

. When replacing the lamp - isolate

the fitting from the supply before

opening the glass front. If the lamp

was recently turned off do not touch

the lamp tube with bare hands.

Please follow lamp manufacturers

instructions when fitting the lamp.

3

. If glass cover becomes cracked,

replace immediately before using the

lamp again.

OPERATION

The infrared detector is equipped with

two adjusting controls, see Fig.

3.

below.

Time Control

The time adjustment control adjusts

the lighting period of the lamp after the

detection of movement. This period is

adjustable from

9

secs to

10

mins. Turn

the control clockwise to increase the

lighting period and anti-clockwise to

reduce the lighting period.

Fig.

2

TXPIR120 Instructions final:Layout 1  17/6/13  12:02  Page 1