Green Brook KingShield T206-C Installation And Operating Instruction Download Page 2

Dia.

8

HOW TO ‘OPERATE’ COUNTDOWN TIMER

WITHIN DEFAULT SETTING

1.

Press and hold ‘Set’ button to set the count

down time required. (The display will increase 

by 15 minute steps in default mode upto the 

limit of 

hours). Dia.

4

.

2

. Release the ‘Set’ button when the desired time 

is shown, limit is now set. Dia.

5

.

3

. Press ‘Start’ button to start or pause the 

countdown timer. Dia.

6&7.

Note:

Pressing the ‘Start’ button to pause the 

countdown timer when the timer is running 

will turn off power until ‘Start’ is pressed again.

To reset countdown from full countdown time, 

turn isolation switch off and then on.

‘On’ indicator will flash 

2

minutes before timer 

reaches ‘

00.00

’ time.

The Countdown timer will stop automatically, if 

any setting is changed.

HOW TO ‘PROGRAM’ FOR 

INDIVIDUAL REQUIREMENTS

1

. Press and hold the ‘+’ and ‘-’ buttons for 

2

seconds to enter the default password Dia.

8

.

To 

Change the password.

Dia:

13

.

Press ‘+’ or ‘-’ buttons to select the ‘PSW’ and then

press ‘Set’ button to confirm.

Use the ‘+’ or ‘-’ button to change 

1

st digit as 

required, press ‘Set’ to confirm and move to 

2

nd

digit, repeat for all 

4

digits. Pressing ‘Set’ after 

4

th

digit will revert timer to operating mode.

2

. Press the ‘+’ or ‘-’ button to select ‘STEP’, ‘CDT’ 

or ‘PSW’ setting.

Note: Password must be entered before any ‘STEP’,

‘CDT’ or ‘PSW’ changes can be made.

PRESS SET THEN:

A: 

Press the ‘+’ or ‘-’ button to set the ‘STEP’ 

required i.e 

15

mins, 

30

mins or 

1

hour. Press the

‘Set’ button to confirm and move to ‘CDT’.Dia:

11

.

B:

Adjust (limit) the amount of hours the 

countdown timer can be used for - (i.e. 

1/4

hour

upto 

23 

hours)Dia:

8

. ‘CDT’ showing on screen.

Press ‘+’ or ‘-’ button to select maximum amount of

countdown hours up to 

23, 

and then press ‘Set’ 

button to confirm.

Note:

Settings will return to operating mode, if no 

buttons are pressed within 

60

seconds.

If ‘+’ or ‘-’ button is held for more than 

seconds, the selected digit will add or decrease 

quickly (about 

3

steps per second)

Settings will return to operating mode 

immediately, if ‘Set’ button is held for more 

than 

2

seconds.

When power is switched off the timer will 

automatically reset to the last saved 

programmed setting. 

The setting will NOT be saved if mains power 

goes off whilst programming.

If no new program has been input, timer will 

re-set to default setting.

Dia.

9

Dia.

10

Dia.

11

Dia.

12

Dia.

13

Dia.

4

Dia.

5

Dia.

6

Dia.

7

WIRING DIAGRAM

T

206

Out

Time Switch

13

A Fuse

Isolation Switch

L

N

N

L

TECHNICAL DIAGRAM

Appliance

Out

In

In

Note:

This product is 

designed to fit in a

25

mm, 

35

mm or

40

mm metal or plastic

back boxes.There is an

additional pattress for

mounting on 

25

mm

boxes.

Allowable Maximum

Load for Lighting 

Circuits:

1,000

W incandescent,

1000

W Halogen, 

500

W

Fluorescent, 

100

W

Compact Fluorescent.

1000

W LED’s.

‘ON’ Indicator

Dia.

1

Fuse

Holder

Double Pole 

Isolation Switch

Front Cable

Entry

Set

Button

Reset

Button

Start/Pause

Button

‘+’ and ‘

-

Button

Display Codes:

STEP = Countdown Time Steps   CDT = Countdown Time   PSW = Password

Note - A separate label has been included in this pack to be located at

the installation site to instruct basic operation.  We suggest that if this

unit is to be password protected that the Purchaser/Site Manager 

retain the full instructions.

Reviews: