Please note, this safety extra low voltage (SELV) fan and its supply 

controller must be installed by a fully qualified electrician in compliance

with current I.E.E and appropriate local regulations. In order to satisfy 

current building regulations, correct fan selection and installation 

practices must be applied.

P

PO

OS

SIIT

TIIO

ON

NIIN

NG

G  T

TH

HE

E  C

CO

ON

NT

TR

RO

OL

LL

LE

ER

R

It is a requirement of I.E.E. regulations that the controller is installed in a

position that is out of reach of a person using a bath or shower. Controller

models which do not have a humidistat may be fitted outside the room

containing the fan.

Humidistat models must be fitted inside the room containing the fan and

sited as high on the wall as possible, but not within 

50

mm of the ceiling

and adjacent wall. All controller models must not be installed in a shower

cubicle, above a bath or where there is any possibility of liquid spray. They

must not be installed where the normal air temperature may exceed 

40

°C

or in an area containing excessive levels of grease.

Fan controllers should not be covered with any heat insulating material, air

flow around the fitting should not be restricted. Note 

50

mm minimum

distance to all adjacent surfaces. All models come complete with a patress

box but can be flush wall mounted by using a suitable 

25

mm deep fixing

box.

INSTALLATION / OPERATING INSTRUCTIONS 

FOR 12V FAN CONTROLLER RANGE

MODEL NUMBERS: 

12

VFC / 

12

VFCPC / 

12

VFCT / 

12

VFCTPC / 

12

VFCHS / 

12

VFCHSPC