GREEN BANK XMJ24200 User Manual Download Page 4

LiFePO4 Battery System for Households

05

04

LiFePO4 Battery System for Households

Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You 
should have received the following items inside of package.

3.1 Unpacking and Inspection

3.2 Mounting the Unit

Consider the following points before selecting where to install:
• Do not mount the battery on flammable construction  materials.
• The ambient temperature should be between 0°C and 45°C to ensure optimal operation.
• The recommended installation position is to be adhered to the wall vertically.
• Be sure to keep other objects and surfaces as shown in the right diagram to guarantee sufficient heat dissipation and 
  to have enough space for removing wires.

NO             

NAME                          

SPECIFICATION

PICTURE

User manual

User manual

Guarantee card

Guarantee card

Cables

Screw

Mounting screw

Wall mount

Wall mount bracket

1

4

5

3

2

Used for battery parallel connection

3. INSTALLATION

2

3

4

5

105

240

111

301

155

140

92.5

320

232.5

401

132.5

240

A

B

C

D

E

F

XMJ24200

XMJ48200

2.3 Specifications

2.

4

 Recommended Settings

Lithium battery pack is not same as lead-acid battery, so for the devices which you connect with the battery pack 
for charging or discharging, such as inverters, MPPT charger controllers or UPS, please implement pre-settings 
as recommended settings as below before you launched them.

Setting 

Max. Charging Voltage 

 

Floating charging Voltage

Recommend Charge Current

Cut-off voltage

Notes: “N” means the number of battery packs connected in parallel.

Model

Usable Capacity

Voltage Range

MAX. Charge & Discharge Current

 

Recommend Discharge Current

MAX. Output Power

Recommend Output Power

DOD

Modules Connection

Ingress Protection

Cycle Life

Working Temperature Range

Net Weight(KG) 

Gross Weight(KG)

Product Dimension(MM)

Package Dimension(MM)

95%

1~6in parallel

IP21         

≥3000,@25°C,@DOD80%

Discharge: -20°C to +60°C, Charge: +0°C to +55°C

XMJ24200 

5KWH

XMJ24350 

XMJ48200 

XMJ48350

10KWH

8.4KWH

16.8KWH

21-28.2

42-56.4

21-28.2

42-56.4

120A @30S

150A @30S

≤60A

≤100A

3000W

6000W

7500W

3750W

1500W

3000W

5000W

2500W

       73.2KG

       151.0KG

      78.4KG

      162.6KG

XMJ24200 

XMJ24350 

XMJ48200 

XMJ48350

28.2V

56.4V

28.2V

56.4V

45A*N

90A*N

45A*N

90A*N

24V

48V

578*578*235MM

380*563*758MM

690*690*347MM

475*668*925MM

      50KG

      53KG

      510*450*213MM

    622*562*292MM

       88.5KG

      93.1KG

      800*545*213MM

     912*657*292MM

Nominal Voltage

Recommend Charge Current    

≤45A 

≤90A 

NOTE:

 ①

 

 

 in XMJ24350 & XMJ48350  

 

 

 

④ ⑤

 in XMJ24200 & XMJ48200

1

Total capacity

3.75KWH

7.5KWH

7.5KWH

15KWH

Reviews: