109
5. Remove right side panel
Remove the screws holding the right side panel to the chassis,
valve support and electrical box. Remove the right side plate
assembly.
Remove the screws connecting the left side plate to the chassis,
then remove it.
6. Remove the axial flow fan
Remove the nuts holding the blade, then remove the blade.
Remove the srews holding the motor, disconnect the leading
wire insert of the motor. Remove the two tapping screws holding
the motor support and then pull the motor support upwards to
remove it.
7. Remove electric box assembly
Remove the srews holding the electric box sub-assy, then loosen
the wire bundle. Pull out the wire terminals and then pull the
electric box upwards to remove it.
Disassembly of Outdoor Unit, continued
18,000 btuh
Warning - Wait 10 minutes after power is disconnected before starting disassembly
.
Right side
plate
Left side plate
Electric box
Axial fan blade
Fan motor
Fan motor
frame