Fig.
Fig.
Fig.
Capillary
Bolt
Bolt
Liquid valve
Gas valve
4pcs soldered point
Solenoid coil
Operation procedures/pictures
Disassemble four-way valve
To remove the tighten nut from the 4-way valve
loop, take out the loop, and wrap the 4-way valve
with wet gauze, then unsolder the soldered point
which connect on the 4-way valve (4pcs for each
4-way valve), take off 4-way valve.
The soldering procedures should be as quickly as
possible, and should keep the gauze wet, please
note do not burn the compressor lead by soldering
flame. As shown in Fig. 8-46;
Remove the capillary
Unsolder 2pcs capillary assy and 4pcs soldered point
which connected liquid valve and condenser outlet pipe,
take off the capillary sub-assy. As shown in Fig.8-47:
Remove gas valve and liquid valve
Remove 4pcs bolt which fix two gas valve, unsolder
the soldered point which connect the gas valve and
air return pipe, take off gas valve. (Note: When
unsolder the soldered point, the gas valve should be
entirely wrapped with wet cloth, avoid the valve be
damaged by high temp.) screw off 4pcs bolt which
fix the liquid valve, take off liquid valve.
As shown in Fig.8-48;
Ultra thin split unit series
Summary of Contents for KFR-35GW/NaA512
Page 1: ...1 Summary and features Models Remarks Ultra thin split unit series...
Page 2: ...Remarks Models...
Page 3: ...Remarks Models Ultra thin split unit series...
Page 11: ...Handle Screw Nut Spanner Ultra thin split unit series...
Page 14: ...6 6 6 6 6 Circuit diagram...
Page 49: ...Explosive view for outdoor unit of single split type unit Ultra thin split unit series...
Page 51: ...Ultra thin split unit series Explosive view for indoor unit of dual split type unit...
Page 53: ...Ultra thin split unit series Explosive view for outdoor unit of dual split type unit...