Operation procedures/pictures
Fig.
Fig.
Fig.
Disassemble the capillary
Unsolder the double end of the capillary, can disassemble
the capillary, do not let the dregs block the capillary.
(As shown in Fig.8-47)
Disassemble the valve
Using the screwdriver to screw off 2pcs screw which
fix the valve, then unsolder the copper pipe which
connect with the valve. Then could disassemble the
valve. (As shown in Fig.8-48)
Disassemble the compressor
Unsolder the copper pipe which connect with the
compressor, and screw off 3pcs base nut with spanner,
can disassemble the compressor.(As shown in Fig.8-49)
Capillary assy
Gas valve
Liquid valve
Solder joint
Base nut
Summary of Contents for KFR-32GW/NA21
Page 1: ...1 Summary and features Models Remarks Bird Single Split Type...
Page 2: ...Models Remarks...
Page 3: ...Remarks Models Bird Single Split Type...
Page 4: ...Models Remarks...
Page 28: ...320 Handle Spanner Nut Bolt above above above above...
Page 29: ...Bolt Nut Spanner Handle above above above above Bird Single Split Type...
Page 30: ...Handle Bolt Nut Spanner above above above above...
Page 32: ...6 6 6 6 6 Circuit diagram...
Page 33: ...Bird Single Split Type...
Page 34: ......
Page 35: ...Bird Single Split Type...
Page 36: ......
Page 37: ...Bird Single Split Type...
Page 38: ......
Page 39: ...Bird Single Split Type...
Page 40: ......
Page 41: ...Bird Single Split Type...
Page 77: ...9 Explosive view and spare parts list Explosive view of indoor unit Bird Single Split Type...
Page 96: ...T he explosive view of the small outdoor unit...
Page 103: ...Disassembly of Components of Big Outdoor Unit Bird Single Split Type...
Page 118: ...Disassembly of Components of Plastic Case Outdoor Unit...