Receiver JS13
12
When using the remote control to set and display the indoor or outdoor
temperature, the temperature display area will display indoor or outdoor
temperature for 3s and then switch to display the corresponding set
temperature value.
(3) Under normal operation, when the remote control switches the light on or
off, the remote signal receiver will switch between display and black screen.
When the lights are off, they all go out. At this time, when the remote control
signal is received, it will display normally for 3s and then go out. The light is
defaulted to be on after energization.
(4) Temperature value is displayed in Celsius or Fahrenheit and its unit °C or °F
is not displayed.
(5) When the centralized controller has set partial shielding or full shielding
function, if using a remote control to control the receiver, the receiver’s
buzzer will give out an invalid operation sound (the buzzer quickly responds
twice). When the centralized controller has set energy-saving function, if the
temperature set by the remote control exceeds the upper limit or lower limit
temperature, the buzzer will give out an invalid operation sound (the buzzer
responds twice quickly).
5 Display of Error Codes
When error occurs in the system, temperature display window will display error
code. When multiple errors occur simultaneously, it will circularly display error codes.