5
Condensing Unit
Service Manual
PRODUCT
4.3 Electrical Data
Indoor unit
Power Supply
Fan Motor FLA
Fuse/Breaker
Capacity
Min. Power
Supply Cord
V/Ph/Hz
A
A
mm
2
HNTF24/A-D
220-230,1,60
0.65
15
1.3
HNTF36/A-D
220-230,1,60
0.65
15
1.3
HNTF48/A-D
220-230,1,60
1.6
15
1.3
HNTF60/A-D
220-230,1,60
1.6
15
1.3
Notes:
RLA:Rated load amperes
LRA:Locked rotor amperes
FLA:Full load current
a.
Install the disconnect device with a contact gap of at least 3mm in all poles nearby the units (Both
indoor unit and outdoor unit).The appliance must be positioned so that the plug is accessible.
b. The specifications of the breaker and power cable listed in the table above are determined based on
the maximum power (maximum amps) of the unit.
c.
The specifications of the power cable listed in the table above are applied to the conduit-guarded
multi-wire copper cable (like, YJV copper cable, consisting of PE insulated wires and a PVC cable jacket) used
at 40°С and resistible to 90°С(see IEC 60364-5-52). If the working condition changes, they should be modified
according to the related national standard.
d.
The specifications of the breaker listed in the table above are applied to the breaker with the working
temperature at 40°С. If the working condition changes, they should be modified according to the related national
standard.
Summary of Contents for HNTF24/A-D
Page 1: ...Condensing Unit Service Manual T1 R410A 60Hz GC201408...
Page 3: ...1 Condensing Unit Service Manual PRODUCT PRODUCT...
Page 8: ...6 Condensing Unit Service Manual CONTROL CONTROL...
Page 20: ...18 Condensing Unit Service Manual INSTALLATION...
Page 32: ...30 Condensing Unit Service Manual MAINTENANCE...
Page 45: ...JF00302341...