1. Requirement of malfunction display
When several malfunctions happen at the same time, malfunction codes will be displayed circularly.
2. Malfunction display method
(1) Hardware malfunction: it will be displayed immediately, please refer to “Malfunction status sheet”;
(2) Operation status: it will be displayed immediately, please refer to “Malfunction status sheet”;
(3) Other malfunction: It will be displayed after the compressor has been stopped for 200s, please refer to “Malfunction
status sheet”.
(Note: when the compressor starts up again, malfunction display waiting time (200s) will be cleared.)
3. Malfunction display control
Indoor unit displays malfunction code as shown in the sheet below. ODU communication light will be off for 1s and then blink
for 1s circularly.
4. Viewing malfunction code through remote controller
Enter viewing malfunction code: pressing light button for 6 times within 3S to view malfunction code;
Exit viewing malfunction code: pressing light button for 6 times within 3S or after the malfunction code is displayed for 5min.
Malfunction status sheet
Malfunction name
Malfunction type
Nixie tube
Zero cross detection circuit malfunction
Hardware malfunction
U8
Malfunction protection of jumper cap
Hardware malfunction
C5
Feedback of without IDU motor
Hardware malfunction
H6
Indoor ambient temperature sensor is open/short circuited
Hardware malfunction
F1
Indoor evaporator temperature sensor is open/short circuited
Hardware malfunction
F2
Liquid valve temperature sensor is open/short circuited
Hardware malfunction
b5
Gas valve temperature sensor is open/short circuited
Hardware malfunction
b7
Modular temperature sensor is open/short circuited
Hardware malfunction
P7
Outdoor ambient temperature sensor is open/short circuited
Hardware malfunction
F4
Outdoor condenser inlet pipe temperature sensor is
open/short circuited (commercial)
Hardware malfunction
A5
Outdoor condenser middle pipe temperature sensor is
open/short circuited
Hardware malfunction
F4
Outdoor condenser outlet pipe temperature sensor is
open/short circuited (commercial)
Hardware malfunction
A7
Outdoor discharge temperature sensor is open/short
circuited
Hardware malfunction
F5
Communication malfunction
Hardware malfunction
E6
Malfunction of phase current detection circuit for compressor
Hardware malfunction
U1
Compressor demagnetization protection
Viewing malfunction code
through remote controller within
200s; displayed directly on
nixietube after 200s
HE
Malfunction of voltage dropping for DC bus-bar
U3
Module high temperature protection
P8
Refrigerant lacking or blockage protection of system (not
available for residential ODU)
F0
Charging malfunction of capacitor
Hardware malfunction
PU
High pressure protection of system
Hardware malfunction
E1
Low pressure protection of system (reserved)
Hardware malfunction
E3
Summary of Contents for GWHD(18)NK3FO
Page 3: ...6XPPDU DQG HDWXUHV 6XPPDU DQG HDWXUHV 2XWGRRU 8QLW 0RGHOV 3URGXFW RGH 1 2 1 2 1 2 1 2...
Page 8: ...RQVWUXFWLRQ 9LHZV RQVWUXFWLRQ 9LHZV 0RGHO 1 2 8QLW PP 0RGHOV 1 2 1 2 1 2...
Page 24: ...SORGHG 9LHZV DQG 3DUWV LVW SORGHG 9LHZV DQG 3DUWV LVW 0RGHO 1 2...
Page 26: ...SORGHG 9LHZV DQG 3DUWV LVW 0RGHO 1 2...
Page 28: ...SORGHG 9LHZV DQG 3DUWV LVW 0RGHO 1 2...