92
Installation and Maintenance
Service Manual
11.2 Removal Procedure of Outdoor Unit
Remove the screw connecting the big handle
and right side plate, and then remove the big
handle.
Remove the screw connecting the valve cover
and right side plate, and then remove the valve
cover.
Remove the screws connecting the top cover
with outer case, right side plate and left side
plate; lift the top cover upwards to remove it.
handle
right side plate
screws
top cover
a
b
1. Remove big handle,valve cover and top cover
screws
Procedure
Step
Warning: Be sure to wait for a minimum of 20 minutes after
turning off all power supplies and discharge the refrigerant
completely before removal.
valve cover