84
Installation and Maintenance
Service Manual
Procedure
Steps
gas valve
liquid valve
compressor
isolation sheet
12. Remove gas valve and liquid valve
Twist off the 2 bolts fixing the valve
sub-assy. Unsolder the soldering
joint between gas valve and
air-return pipeand then remove the
gas valve.(note: when unsoldering
the soldering joint, wrap the gas
valve with wet cloth completely to
avoid the damage to valve, and
release all refrigerant completely at
first). Unsolder the soldering joint
between liquid valve and connection
pipe of liquid valve, and then
remove the liquid valve.
13. Remove compressor
Twist off the 3 foot nuts on compressor
and then remove the compressor.
14. Remove isolation sheet
Twist off the screws connecting
isolation sheet and end plate of
condenser and chassis, and then
remove the isolation sheet.