130
Installation and Maintenance
Service Manual
6.Remove soundproof sponge
Since the piping ports on the soundproof sponge are
torn easily, remove the soundproof sponge carefully
.
soundproof sponge
7. Remove
Isolation sheet
Remove the 3 screws fixing the isolation sheet
and then remove the Isolation sheet.
Isolation sheet
8. Remov e 4-way valv e assy
Discharge the refrigerant completely;unsolder
the pipelines connecting the compressor and
the condenser assy,and then remove the 4-way
valve assy.
4-way valve assy
Steps
Procedure