64
Installation and Maintenance
Service Manual
Procedure
Step
Remove one screw on magnetic coil, and
then remove the magnetic coil.
Unsolder the spot weld between capillary with
valve and condenser; remove two screws
fixing the gas valve; unsolder the spot weld
connecting gas valve and air-return pipe, and
then remove the gas valve.
Remove two screws fixing the liquid valve;
unsolder the spot weld connecting liquid valve
and Y-type pipe, and then remove the liquid
valve.
Note:
When unsoldering the spot weld, wrap the
gas valve with wet cloth completely to avoid
damaging the valve due to high temperature.
Magnetic coil
10. Remove magnetic coil
11. Remove gas valve and liquid valve
S
crew
Liquid valve
G
as valve
S
crews
S
crews
C
apillary sub-assy
Capillary sub-assy
4-way valve assy
12. Remove 4-way valve assy and capillary sub-assy
Unsolder the spot weld of 4-way valve assy,
capillary, compressor and condenser, and
then remove the 4-way valve assy and
capillary sub-assy.
Note:
When unsoldering the spot weld, wrap
the 4-way valve with wet cloth completely
to avoid damaging the valve due to high
temperature.