90
Installation and Maintenance
Service Manual
a
b
13. Remove liquid valve and gas valve
14. Remove compressor
Unsolder pipes connecting with compressor.
Remove the 3 foot nuts on the compressor
and then remove the compressor.
Unsolder the welding joint connecting the capillary,
valves and the outlet pipe of condenser to remove
the capillary. Do not block the capillary with welding
slag during unsoldering.
Remove the 2 screws fixing the gas valve and
unsolder the welding joint between the gas valve
and the air-return pipe to remove the gas valve.
(NOTE: Discharge the refrigerant completely before
unsoldering; when unsoldering, wrap the gas valve
with a wet cloth completely to avoid damage to the
valve caused by high temperature).
Remove the 2 screws fixing the liquid valve and
unsolder the welding joint connecting the liquid valve
to the Y-type pipe to remove the liquid valve.
liquid valve
gas valve
4-way valve
capillary
foot nuts
compressor