background image

                               

5 ℃

Earth:The ground

be connected!

If not, please ask the qualified person-

nel to install. Furthermore, don't conn-

ect each wire to the gas pipe, water 

pipe, drainage pipe or any other impr-

oper places.

Select the most appropriate tem-

perature.

It can preclude the electricity wasted.

Keep room coo

l

-

er than outside

about 

Don't leave windows and 

doors open for a long time 

while operating the air conditi-

oner.

Don't block the air intake or outlet

vents of both the outdoor and indoor

units.

Keep combustible spray away

from the units more than 1m.

It can cause 

fire

 or explosion.

It can decrease the air conditioning

capacity or cause a malfunction.

It can decrease the air conditioning

capacity.

Please note whether the install-

ed stand is firm

 enough.

If it is damaged, it may lead to

the fall of the unit and cause

injury.

As falling off the outdoor unit

can be dangerous.

Don't step on the top of the

outdoor unit or place something

on it.

Don't attempt to repair

the air conditioner by yourself.

The wrong repair will lead to

electric 

shock or fire, so

you should contact 

with 

the service

center repair

ing

.

Notices for use

The temperature of refrige-

rant circuit will be high, please
keep the interconnection cable 

away from the copper tube. 

The appliance shall not be 

installed in the laundry.

Summary of Contents for GWCN24 B9NK1BA

Page 1: ...1BA OWNER S MANUAL Models Thank you for choosing GREE air conditioner for correct operation please read this owner s manual carefully before operating the unit and keep it carefully for consultation G...

Page 2: ...ng Installation service Notices for installation Install indoor unit Install outdoor unit Test operation and check after installation Thank you for choosing this air conditioner please read this owner...

Page 3: ...usts that may cause overheating or fire Never damage the electric wire or use the electric wire which is not appointed Otherwise it will cause overheating or fire When cleaning it is necessary to stop...

Page 4: ...can cause fire or explosion It can decrease the air conditioning capacity or cause a malfunction It can decrease the air conditioning capacity Please note whether the install ed stand is firm enough...

Page 5: ...er for other purposes such as drying clothes preserving foods etc Notices for use To adjust the airflow and direction appropriately At operating the louvers of air conditioner could be adjusted by pre...

Page 6: ...bove parameters are tested according to GB T7725 2004 moreover the cooling capacity heating capacity noise index are tested before leaving factory The max input power are tested under the max cooling...

Page 7: ...equipments Defrosting Whenoutdoortemperatureislowbutwithhighhumidity afteralongwhilerunning frostwillformonoutdoorunit thatwillaffecttheheatingeffect atthistime theautodefrostingfunctionwillact thehe...

Page 8: ...s remote control Names and functions of each part Air in Air out Filter Guide louver Wall pipe Bind tape Receiving window Connectionwire Indicator Drainage pipe Front panel DRY SET TEMP RUN COOL HEAT...

Page 9: ...perature will be changed quickly Thetemperaturesettingrangeis16 30 COOL HEAT COOL button HEAT button At operating pressing this button could enter into the COOL mode directly At operating pressing thi...

Page 10: ...F At AUTO FAN or HEAT modes the BLOW function cannot be set and there is no BLOW displayed Pressing this button enter into SLEEP state or quit the SLEEP state After unit is turned off and cancel the S...

Page 11: ...on may be not available for some units 4 Press TURBO button can realize the ON and OFF of TURBO function The above operation please refers to Page 7 Page 8 for details Introduction for special functio...

Page 12: ...can cause the malfunction of the wireless remote control take them out and don t let the leakage liquid damage the wireless remote control The operation should be in its receiving range It should be...

Page 13: ...into the slots along the direction of arrows cover and clasp the front panel As show in Fig 4 a b Fig 4 Along the arrowhead direction open an angle at both slots of front panel then pull the air filt...

Page 14: ...stallationstandoftheoutdoor unitisdamagedornot Ifdamaged pleasecontactthedealer Maintain after use Turn main power off Clean the filter as well as indoor and outdoor units bodies Clear dust and obstru...

Page 15: ...act with our authorized maintenance center There s unusual smell blowing from the outlet after operation is started Sound of water flow can be heard during the operation When unit is started when oper...

Page 16: ...ert it Is it in its receiving range Or obstructed On Page 7 Check the voltage in wireless remote control batteries On Page 10 inside is charged otherwise replace the Whether the wireless remote contro...

Page 17: ...r to avoid condensing water be vaporized again restrain temperature rising defrosting there is water flowing out or vapor be produced Indoor unit cannot deliver air If unit is running under the high h...

Page 18: ...ter can be easily drained out and the place is easily connected for outdoor unit Select a location where children can not reach Select the place where is strong enough to withstand the full weight and...

Page 19: ...nctions of magnetic tripping and heat tripping in order to protect the short circuit and overloading The min distance from the unit and combustive surface is 1 5m The outside static pressure is 0MPa w...

Page 20: ...he ceiling Space to the wall Space to the wall Air outlet side Space to the obstruction Space to the wall Air intake side Air outlet side Space to the wall Above Above Above Above Above Above Above A...

Page 21: ...placed at a downward slant Do not wrench or bend the drain pipe or flood its end by water 2 3 When the long drainage pipe passing through indoor wrap it with insulation materials Wrenched Bent Flooded...

Page 22: ...tailings 1 and tailings 2 when routing both the wiring and piping Take out the piping from body case wrap the piping electric wire water pipe with tape and put them th rough the piping hole As show i...

Page 23: ...hen connect the corresponding connector Ensure wire has been fixed well Power Install the Supply front side plate signal connetion wire connecting power cord Note cooling and heat pump type Wrong wiri...

Page 24: ...or leakage detector to test if the outdoor unit and pipeline connection leak Air purging and leakage test Take out the nut cover of the inlet for refrigerant Align the center of the piping and tighten...

Page 25: ...Has the unit been connected to a secure earth connection It may cause electrical leakage Is the power cord specified It may cause electric malfunction or damage the part Is the inlet and outlet been...

Reviews: