background image

14

Child lock function

Press "▲" and "    " simultaneously to turn on or turn off child lock function. When

child lock function is on, "    " icon is displayed on remote controller. If you operate

the remote controller, the "    " icon will blink three times without sending signal to

the unit.

8

 heating function

Under heating mode, press "TEMP" and "CLOCK" buttons simultaneously to start

 heating function. When this function is started up, "     " and "8

will be shown on remote controller, and the air conditioner keep the heating status 

. Press "TEMP" and "CLOCK" buttons simultaneously again to exit 8

up or turn off 8

at  8

heating function.

Note:

● Under 8

 heating function, fan speed is defaulted at auto speed and it can’t be

   adjusted.

● Under 8

 heating function, set temperature can’t be adjusted. Press "TURBO" 

   button and the remote controller won’t send signal.

● Sleep function and 8

 heating function can’t operate at the same time. If 8

  heating function has been set under cooling mode, press sleep button will cancel 

   8

 heating function. If sleep function has been set under cooling mode, start up 

   the 8

 heating function will cancel sleep function. 

● Under 

 temperature display, the remote controller will display 46

 heating.

Function introduction for combination buttons

Temperature display switchover function

Under OFF status, press "    " and "MODE" buttons simultaneously to switch temp-

erature display between 

 and 

.

Summary of Contents for GWC09QC-A3DNA1D/I

Page 1: ...r choosing our product If you have lost the Owner s Manual please contact the local agent or visit www gree com or sent email to global gree com cn for electronic version For proper operation please r...

Page 2: ...D3DNB4D I GWH12QC A3DNB4D I GWC18QD D3DNA1D I GWC18QD D3DNB2D I GWC12QC D3DNA5D I GWC18QD D3DNA5D I GWC09QC D3DNB8D I GWC09QC A3DNB8D I GWC12QC D3DNB8D I GWC12QC A3DNB8D I GWH18QD D3DNB2D I GWH18QD D3...

Page 3: ...GWH24QE D3DNA5D I GWH24QE D3DNB2D I GWH24QE D3DNB4D I GWH24QE D3DNB8D I GWH24QE D3DNA3D I GWC24QE D3DNA2D I GWH24QE D3DNA2D I GWC24QE D3DNB8D I GWC24QE D3DNA3D I GWC24QE D3DNB2D I GWC24QE D3DNA5D I G...

Page 4: ...ram 23 Tools for installation 24 Selection of installation location 24 Requirements for electric connection 25 Installation Installation of indoor unit 26 Check after installation 31 Test and operatio...

Page 5: ...s situation that if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard re...

Page 6: ...appliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory ormental capabilities or lack of experience and know...

Page 7: ...amage 2 Precautions conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not spill...

Page 8: ...fore using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket Properly...

Page 9: ...nnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only 4 Precautions wire which can t be used for other purposes The grounding resistance should...

Page 10: ...onditioner to another must be installed in the line For the air conditioner without plug an circuit break Select a location which is out of reach for children and For the air conditioner with plug the...

Page 11: ...rent from above graphics please refer to actual products Parts Name Indoor Unit air inlet panel aux button horizontal louver air outlet remote control Actual product may be different from above graphi...

Page 12: ...r display For some model For some model For some model For some model heating indicator temp indicator cooling indicator power indicator receiver window drying indicator display G W R Power LED color...

Page 13: ...N TIMER OFF button SLEEP button button Send signal Turbo mode 8 heating function Set temperature Set time TIMER ON TIMER OFF Child lock Up down swing Set fan speed Light Temp display type Set temp Out...

Page 14: ...nditioner will give out a sound Operation indictor is ON red indicator After that you can operate the air conditioner by using remote controller Under on status pressing the button on the remote contr...

Page 15: ...button above 2s to set your required swing angle When reaching your required angle release the button Note may not be available When air conditioner receives this signal the air conditioner will blow...

Page 16: ...e indicator on indoor unit displays outdoor ambient temperature Note Outdoor temperature display is not available for some models At that time indoor unit receives signal while it displays indoor set...

Page 17: ...1 TIMER ON TIMER OFF button 12 TIMER ON button TIMER ON button can set the time for timer on After pressing this button icon disappears and the word ON on remote controller blinks Press or button to a...

Page 18: ...button 2s later the time will change quickly until reaching your required time Press TIMER ON to confirm it The word ON will stop blinking icon resumes displaying Cancel TIMER ON Under the condition...

Page 19: ...t 8 heating function Note Under 8 heating function fan speed is defaulted at auto speed and it can t be adjusted Under 8 heating function set temperature can t be adjusted Press TURBO button and the r...

Page 20: ...two 7 AAA 1 5V dry batteries and make sure the position of polar and polar are correct 3 Reinstall the cover of battery box signal sender battery Cover of battery box remove reinstall During operatio...

Page 21: ...enance Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not wash the air conditioner with water to avoid electric shock Do not use v...

Page 22: ...d then put it in a shady and cool place to dry panel cover tightly The lter should be cleaned every three months If there is much dust in the operation environment clean frequency can be increased Aft...

Page 23: ...nage pipe is damaged 1 Disconnect power supply Notice for recovery 1 Many packing materials are recyclable materials Please dispose them in appropriate recycling unit 2 If you want to dispose the air...

Page 24: ...oom Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re cei...

Page 25: ...door temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set t...

Page 26: ...ess devices etc Disconnect power put back power and then turn on the unit again Water flowing noise Air conditioner is turned on or turned off just now The noise is the sound of refrigerant flowing in...

Page 27: ...can be eliminated after restarting the unit If not please It can be eliminated after restarting the unit If not please Note service Malfunction analysis When below phenomenon occurs please turn off ai...

Page 28: ...23 Installation dimension diagram At least 250cm At least 15cm At least 300cm Space to the ceiling Space to the obstruction At least 15cm Space to the wall Space to the wall At least 15cm...

Page 29: ...driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench 7 Open end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter 13 Inner hexagon spanner 14 Me...

Page 30: ...er to avoid a hazard 8 The temperature of refrigerant circuit will be high please keep the interconnec tion cable away from the copper tube 9 The appliance shall be installed in accordance with nation...

Page 31: ...piping hole 2 Open a piping hole with the diameter of 55 70 on the selected outlet pipe position In order to drain smoothly slant the piping hole on the wall slightly downward to the outdoor side wit...

Page 32: ...ng out the pipe from left or right please cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction of right rear right left or rear left...

Page 33: ...55 60 65 70 75 15 20 insulating pipe 1 Connect the drain hose to the outlet pipe of indoor unit 2 Bind the joint with tape outlet pipe drain hose drain hose tape outlet pipe drain hose insulating pip...

Page 34: ...ircuit break should be all pole parting and the contact parting distance should be more than 3mm 3 Remove the wire clip connect the power connection wire to the wiring terminal with wire clip power co...

Page 35: ...parately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the i...

Page 36: ...ower cord follow the speci cation It may cause malfunction or damaging the parts Is there any obstruction in the air inlet and outlet It may cause insuf cient cooling heating capacity The dust and sun...

Page 37: ...l refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refrigerant charging amount prolonged length of liquid pipe additional...

Page 38: ...4a Diameter of connection pipe Liquid pipe mm Gas pipe mm 6 6 or 9 52 12 16 19 22 2 9 52 or 12 16 or 19 19 or 22 2 25 4 or 31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350...

Page 39: ...suitable insulating pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe union pipe pipe E Expand the port Expand the por...

Page 40: ...Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com GREE ELECTRIC APPLIANCES INC OF ZHUHAI 66160000086...