5HPRYDO3URFHGXUH
a
b
5. Remove axial flow blade and motor
Remove the nut on the blade. Remove the axial
flow blade.
Remove the tapping screws fixing the motor;
disconnect the leading wire insert of the motor.
Remove the motor. Remove the tapping screws
fixing the motor support. Lift the motor support to
remove it.
Remove screws fixing the electric box subassembly.
Loosen the wire bundle; unplug the wiring terminals
and lift the electric box to remove it.
6. Remove electric box
electric box
motor
motor support
axial flow blade