background image

2

3

Install indoor unit

4.

2.

3.

 

1.

1.
2.

Install the indoor unit

The piping can be lead out from right, right rear, left

left rear.

When routing the piping and wiring from the left

or right side of indoor unit, cut off the tailings

from the chassis in necessary(Show in Fig.7)

(1)Cut off the tailings 1 when routing the wiring only;

(2)Cut off the tailings 1 and tailings 2 when routing

both the wiring and piping. 

Take out the piping from body case, wrap the piping

electric wire, water pipe with tape and pull them

through the piping hole (As show in Fig.8)

Hange the mounting slots of the indoor unit on the

upper tabs of the rear panel and check if it is firm

enough.(As show in Fig.9)

The height of the installed location should be 2. m

or more from the floor.

Install the connection pipe

Align the center of the piping flare with the relevant valve.

Screw in the flare nut by hand and then tighten the

nut with spanner and torque wrench refer to the 

following:

NOTE: Firstly connect the connection pipe to indoor unit, then to outdoor unit; pay attention

to the piping bending, do not damage the connection pipe; the joint nut couldn't tighten too

much, otherwise it may cause leakage.

Spanner

Torque 

wrench

Piping

Taper nut

Indoor unit piping

Fig.9

Mounting

plate

Fixing hook

Mounting 

baord

Right

Right rear

Fig.8

Left rear

Left

Fig.7

Tailing 1

Tailing 2

Finally wrap it

with tape

Gas side piping

insulation

Water drainage pipe

Liquid side

Piping insulation

Gas side pipe

External connection

electric wire
Liquid side piping

          (N·m)

Ф

6

Ф

9.52

Ф

12

31~35

15~20

50~55

Ф

16

60~65

Ф

19

70~75

Hex nut diameter

Tightening torque

5

Summary of Contents for GWC07NA-K3NNB1A

Page 1: ...fe Split Air Conditioner Owner s Manual Residential Air Conditioners Thank you for choosing Residential Air Conditioners please read this owner s manual carefully before operation and retain it for future reference ...

Page 2: ...NB3A GWH09NA K3NNB3A GWH18ND K3NNB3A GWH12NB K3NNB4A GWH24ND K3NNB4A GWH07NA K3NNB4A GWC12MB K3NNC1A GWC18ND K3NNB1B GWC18ND K3NNB2B GWC18ND K3NNB3B GWC18ND K3NNB4B GWH09NA K3NNB4A GWH18ND K3NNB4A GWC24ND K3NNB3B GWH07NA K3NNB3A GWH09NA K3NNB3B GWC09NA K3NNB3C GWC09NA K3NNB3B GWC12NB K3NNB3B GWC15NC E1NNB3A GWC09NA K3NNB1B GWC12NB K3NNB1B GWC09NA K3NNB2B GWC12NB K3NNB2B GWC24ND K3NNB1B GWC24ND K3N...

Page 3: ...GWH24ND K3NNB5A GWH24ND K3NNB6A GWH24ND K3NNB7A GWH12NB K3NND2A GWH24ND K3NNB8A ...

Page 4: ...NA3A GWH18ND K3NNA3A GWH07NA K3NNA3A GWH09NA K3NNA3A GWH07NA K3NNA4A GWH09NA K3NNA4A GWH18ND K3NNA4A GWH12NB K3NNA4A GWH24ND K3NNA3A GWH24ND K3NNA4A GWC18ND K3NNA3B GWC18ND K3NNA4B GWC09NA K3NNA2B GWC12NB K3NNA2B GWC09NA K3NNA3B GWC12NB K3NNA3B GWC24ND K3NNA3B GWC24ND K3NNA2B GWC18ND K3NNA2B ...

Page 5: ...07NA K3NNA5A GWH09NA K3NNA5A GWH12NB K3NNA5A GWH18ND K3NNA5A GWH18ND K3NNA8A GWH12NB K3NNA8A GWH09NA K3NNA8A GWH07NA K3NNA8A GWC18ND K3NNA5B GWC18ND K3NNA8B GWC09NA K3NNB2C GWC09NA K3NNA8C GWC09NA K3NNA8B GWC12NB K3NNA8B GWC24ND K3NNA8B GWC09NA K3NNA5B ...

Page 6: ...al volume of refrigerant Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary The products in this manual may be different with the real one according to different models some models have displayer and some models without displayer the position and shape of the displayer please refer to the real one This appliance is not int...

Page 7: ...en for a long time while operating the air conditioner It can decrease the air conditioning capacity Don t block the air intake or outlet vents of both the outdoor and indoor units It can decrease the air conditioning capacity or cause a malfunction Keep combustible spray away from the units more than 1m It can cause a fire or explosion If it is damaged it may lead to the fall of the unit and caus...

Page 8: ...uver of left right direction Louver of upward downward direction Don t insert your hands or stick into the air intake or outlet vents Otherwise it will cause accident Don t blow the wind to animals and plants directly It can cause a bad influence to them Don t apply the cold wind to the body for a long time It can cause the health problems Don t use the air conditioner for other purposes such as d...

Page 9: ...xchanger when indoor heat exchanger temperature decreased below 0 the indoor unit microcomputer will stop compressor running and protect the unit Air conditioner absorbs heat from outdoor and transmits to indoor in this way to increase room temperature This is the heat pump heating principle its heating capacity will be reduced due to outdoor temperature decrease If outdoor temperature becomes ver...

Page 10: ...unit may blow gentle breeze and the guide louver rotate to a certain position 1 In Heat mode the unit turned on the compressor doesn t arrive the starting condition 2 In Heat mode the temperature arrive at the setting value and the compressor stop running about 1min 27 24 18 The operating temperature range outdoor temperature for cooling only unit is 18 43 for heat pump unit is 7 43 ...

Page 11: ...A8C GWC12MB K3NNC1A GWC12NB K3NNB3B Cooling Cooling Cooling Cooling Cooling 700 1000 Indoor unit 730X255X174 Outdoor unit 720X428X310 0 62kg R410A 821 1000 Indoor unit 730X255X174 Outdoor unit 776X540X320 0 75kg R410A R410A R410A 1075 1500 Indoor unit 790X265X175 Outdoor unit 848X540X320 1 04kg 1004 1450 Indoor unit 790X265X177 Outdoor unit 776X540X320 0 90kg GWC09NA K3NNB1B GWC09NA K3NNB2B GWC09N...

Page 12: ...A 1460 1980 Indoor unit 940X298X200 Outdoor unit 848X540X320 1kg 1900 2600 Indoor unit 940X298X200 Outdoor unit 913X680X378 1 3kg GWC18ND K3NNB1B GWC18ND K3NNB2B GWC18ND K3NNA2B GWC18ND K3NNA3B GWC18ND K3NNA8B GWC24ND K3NNB2B GWC24ND K3NNA3B GWC24ND K3NNA2B GWC24ND K3NNA8B GWC24ND K3NNB1B GWC18ND K3NNB3B GWC18ND K3NNB4B GWC18ND K3NNA4B GWC18ND K3NNA5B Cooling 1495 2040 0 8Kg Indoor unit 940X298X20...

Page 13: ...ating 821 779 1000 1120 Indoor unit 730X255X174 Outdoor unit 776X540X320 0 76kg R410A R410A R410A R410A GWH12NB K3NNB1A GWH12NB K3NNB2A GWH12NB K3NNB3A GWH12NB K3NNA3A GWH12NB K3NNA5A GWH12NB K3NNA4A GWH12NB K3NNA2A GWH12NB K3NNA8A GWH12NB K3NND2A GWH18ND K3NNB1A GWH18ND K3NNB2A GWH18ND K3NNB3A GWH18ND K3NNA3A GWH18ND K3NNA5A GWH18ND K3NNB4A GWH18ND K3NNA2A GWH18ND K3NNA8A GWH18ND K3NNA4A Cooling ...

Page 14: ...oor unit Air in Air out Outdoor unit Wireless remote control Air in Air out Power cable Cool Dry Heat Set temp Run The pattern in displayer Remote control Front panel Filter Guide louver Wall pipe Bind tape Connection wire Drainage pipe 8 ...

Page 15: ...eration mode AUTO COOL DRY FAN HEAT Press it to decrease temperature setting Press it to increase temperature setting FAN Press it to set swing angle TIMER page 11 SLEEP page 10 Press it to set fan speed Press it to set auto on auto off timer 1 2 3 4 5 6 8 7 2 7 4 3 8 6 5 1 SWING Remote Controller Description ...

Page 16: ...above 2 seconds to rapidly decrease set temperature In AUTO mode set temperature is not adjustable Press this button to increase set temperature Hold it down for above 2 seconds to rapidly increase set temperature In AUTO mode set temperature is not adjustable Auto Speed 1 Speed 2 Speed 4 Speed 3 Press this key to activate or deactivate the swing SLEEP 1 2 3 4 5 6 7 AUTO COOL DRY FAN HEAT Note Onl...

Page 17: ...perate normally please take the batteries out and reinsert them after 30 seconds If it still can t operate properly Notes replace the batteries Fig 1 Fig 2 Replacement of Batteries Press and buttons simultaneously to lock or unlock the keypad At unit OFF press MODE and buttons simultaneously to switch between and 4 TIMER Press this button to initiate auto on auto off timer To cancel auto timer pro...

Page 18: ...ture To open the panel the manual switch is on the displayer box Emergency operation was shown as below Turn on the unit At unit turned off press the button the unit will run at Auto mode immediately The microcomputer will accord to the indoor temperature to select Cooling Heating Fan and obtain the comfortable effect Turn off the unit At unit turned on press the button the unit will stop working ...

Page 19: ...our fingers Take down the air filter At the slot of surface panel to open an angle pull the air filter downward and take it out please see the Fig 4 a b To clean the dust adhering to the filters you can either use a vacuum cleaner or wash them with warm water the water with the neutral detergent should below 45 degree and dry it in the shade NOTE Never use water above 45 to clean or it can cause d...

Page 20: ...the dealer Clean and care Check before use Check that whether ground wire is properly connected or not Maintain after use Switch off the power supply Clean the filter and indoor and outdoor units bodies Clear dust and obstructions from the outdoor unit Repaint the rubiginous place on the outdoor unit to prevent it from spreading Adopt the special shield to cover the outdoor unit avoid the rain wat...

Page 21: ...em still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow can be heard during the operation The air conditioner is started when it is running the compressor started or stopped running or the unit is stopped sometimes there is swoosh or gurgle the sound is due to refrigerant flowing they are not malfuncti ons In COOL mode sometimes the m...

Page 22: ...in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged If water leakage in the room The air humidity is on the high side Condensing water over flowed The connection position of indoor unit drainage pipe is loosed If water leakage in outdoor unit When the unit is running...

Page 23: ...thing into unit There is an abnormal heat in power supply cord and power plug Stop running and disconnect the power supply In HEAT mode when the temperature of indoor heat exchanger is very low that will stop deliver air in order to prevent cool air Within 2min In HEAT mode when the outdoor temperature is low or high humidity there are much frost be formed on the outdoor heat exchanger that the un...

Page 24: ...lation Important Notices Basic Requirements For Installation Position Install in the following place may cause malfunction If it is unavoidable contact with service center please Place where strong heat sources vapors flammable gas or volatile object are emitted Place where high frequency waves are generated by radio equipment welders and medical equipment Place where a lot of salinities such as c...

Page 25: ... to the National Criterion 4 The user power must offer the reliable earthing terminal Please don t connect the earthing wire with the following place Tap water pipe Gas pipe Contamination pipe Other places that professional personnel consider them unreliable 5 The appliance shall be installed in accordance with national wiring regulations An all pole disconnection switch having a contact separatio...

Page 26: ...all Air outlet side Space to the floor Above Above 15cm Above 15cm Above Above Space to the obstruction Air outlet side Space to the wall Air inlet side 30cm Above 50cm Above e v o b 50cm A The dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures 20 15cm 250 cm 300cm ...

Page 27: ...into the hole to prevent the connection piping and wiring from being damaged when passing through the hole Install the water drainage pipe Indoor Outdoor Wall pipe Seal pad Fig 5 Wall Wall Mark on the middle of it Gradienter Left Right Rear piping hole Rear piping hole Space to the wall above Space to the wall above 1 Connect the drain hose to the outlet pipe of the indoor unit Bind the joint with...

Page 28: ...p and wiring cover Heat pump type Heat pump type Heat pump type GWC18ND K3NNB1C After tighten the screw slight pull the wire and confirm whether is it firm or not The cover plate must be fixed and tighten the connection wire if it is poor installed that NOTE When connecting the electric wire if the wire length is not enough please contact with the authorized service shop to buy a exclusive electri...

Page 29: ...location should be 2 m or more from the floor Install the connection pipe Align the center of the piping flare with the relevant valve Screw in the flare nut by hand and then tighten the nut with spanner and torque wrench refer to the following NOTE Firstly connect the connection pipe to indoor unit then to outdoor unit pay attention to the piping bending do not damage the connection pipe the join...

Page 30: ...power connection cable and the signal control wire Ensure wire has been fixed well Install the handle 5 1 0 10 pa 76cmHg 1 Connect charging hose of manifold valve to charge end of low pressure valve both high low pressure valves must be tightly shut 2 Connect joint of charging hose to vacuum pump 3 Fully open handle handle of Lo manifold valve 4 Open the vacuum pump to evacuate At the beginning sl...

Page 31: ...voltage in accordance with the rated voltage marked on the nameplate It may cause electric malfunction or damage the part Is the electric wiring and piping connection installed correctly and securely It may cause electric malfunction or damage the part Has the unit been connected to a secure earth connection It may cause electrical leakage Is the power cord specified It may cause electric malfunct...

Page 32: ...tion As for silver ion filter it is invalid when its surface becomes according to the installation instruction Pay special attention to that silver Take out the healthy filter before cleaning and reinstall it after cleaning Installation and Maintenance of Healthy Filter Cleaning and Maintenance Service Life Healthy filter Air filter Healthy filter downwards to remove it See Fig a the front case as...

Page 33: ...additional refrigerant charging amount on the 1 Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging amount per meter 2 When the length of connection pipe is above 5m add refrigerant according to the prolonged length of liquid pipe The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe See Sheet 2...

Page 34: ...er of connection pipe mm Indoor unit throttle Outdoor unit throttle Liquid pipe Gas pipe Cooling only cooling and heating g m Cooling only g m Cooling and heating g m Ф6 Ф9 5 or Ф12 20 15 20 Ф6 or Ф9 5 Ф16 or Ф19 50 15 50 Ф12 Ф19 or Ф22 2 100 30 120 Ф16 Ф25 4 or Ф31 8 170 60 120 Ф19 250 250 250 Ф22 2 350 350 350 Configuration of connection pipe and additional volume of refrigerant ...

Page 35: ...Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com GREE ELECTRIC APPLIANCES INC OF ZHUHAI 66162819 ...

Reviews: