background image

Disconnect the power supply

Clean the air filter

(a)

(b)

Clean and care

Caution

 before cleaning air conditioner, or it may cause electric shock.

Never sprinkle water on the indoor unit and the outdoor unit for cleaning because it can cause an
electric shock.

Volatile liquid (e.g. thinner or gasoline) will damage the air conditioner. (So wipe the units with a
dry soft cloth, or a cloth slightly moistened with water or cleanser.)

Clean the front panel

Clean the air filter (Recommended once every three months)

NOTE: If dust is much more around the air conditioner, the air filters should be cleaned many times.

After taking off the filter, don't touch the fin of indoor unit, in order to avoid hurt your fingers.

Take down the air filter

At the slot of surface panel to open an angle, pull the air filter

downward and take it out, please see the Fig. 4(a, b).

T

o clean the dust adhering to the filters, you can either

use a vacuum cleaner, or wash them with warm water
the water with the neutral detergent should below 45
degree) ,and dry it in the shade.

NOTE: Never use water above 45    to clean, or it can
cause deformation or discoloration. Never parch it by
fire, or can cause a fire or deformation.

Insert the air filter

Reinsert the filters along the direction of arrowhead, and
then to cover the cover and clasp it.

Fig.4

When cleaning the front panel, please dip the cloth into the water temperature of 45     below, then to dry
the cloth and wipe the dirty part.

Note: Please do not to immerse the front panel in water, due to there are microcomputer components and

circuit diagrams on the front panel.

12

Summary of Contents for GWC07NA-K3NNA8A

Page 1: ...e Split Air Conditioner Owner s Manual Residential Air Conditioners Thank you for choosing Residential Air Conditioners please read this owner s manual carefully before operation and retain it for fut...

Page 2: ...8ND K3NNB2A GWH24ND K3NNB3A GWH12NB K3NNB3A GWH09NA K3NNB3A GWH18ND K3NNB3A GWH12NB K3NNB4A GWH18ND K3NNB4A GWH24ND K3NNB4A GWH07NA K3NNB4A GWH09NA K3NNB4A GWC12MB K3NNC1A GWC24ND K3NNB3B GWC09NA K3NN...

Page 3: ...GWH24ND K3NNB5A GWH18ND K3NNB5A GWH07NA K3NNB5A GWH09NA K3NNB5A GWH24ND K3NNB6A GWH24ND K3NNB7A GWH24ND K3NNB8A GWH12NB K3NNB5C GWH09NA K3NNB5C...

Page 4: ...A2A GWH12NB K3NNA3A GWH18ND K3NNA3A GWH07NA K3NNA3A GWH09NA K3NNA3A GWH07NA K3NNA4A GWH09NA K3NNA4A GWH18ND K3NNA4A GWH12NB K3NNA4A GWH24ND K3NNA3A GWH24ND K3NNA4A GWH18ND K3NNA2A GWH12NB K3NNA2C GWH1...

Page 5: ...8ND K3NNA5A GWH18ND K3NNA8A GWH12NB K3NNA8A GWH24ND K3NNA9A GWH09NA K3NNA9C GWH09NA K3NNA8A GWH07NA K3NNA8A GWC07NA K3NNA8A GWH12NB K3NNA9C GWH09NA K3NNA9A GWH24ND K3NNE4A GWH18ND K3NNA9A GWH18ND K3NN...

Page 6: ...7NA K3NNC7A GWH09NA K3NNC7A GWH24ND K3NNC7A GWH12NB K3NNC7A GWH09NA K3NNE1A GWH09NA K3NNE1C GWH12NB K3NNC7C GWH24ND K3NNE1A GWH24ND K3NNE2A GWH12NB K3NND2A GWH12NB K3NND1C GWH12NB K3NNE1A GWH18ND K3NN...

Page 7: ...ollection of such waste separately for special treatment is necessary The products in this manual may be different with the real one according to different models some models have displayer and some m...

Page 8: ...n for a long time while operating the air conditioner It can decrease the air conditioning capacity Don t block the air intake or outlet vents of both the outdoor and indoor units It can decrease the...

Page 9: ...ver of left right direction Louver of upward downward direction Don t insert your hands or stick into the air intake or outlet vents Otherwise it will cause accident Don t blow the wind to animals and...

Page 10: ...changer when indoor heat exchanger temperature decreased below 0 the indoor unit microcomputer will stop compressor running and protect the unit Air conditioner absorbs heat from outdoor and transmits...

Page 11: ...nit may blow gentle breeze and the guide louver rotate to a certain position 1 In Heat mode the unit turned on the compressor doesn t arrive the starting condition 2 In Heat mode the temperature arriv...

Page 12: ...A K3NNE1A GWC07NA K3NND1A GWC09NA K3NNB3B GWC09NA K3NNB3C GWC09NA K3NNE1C GWC12MB K3NNC1A GWC12NB K3NNB3B GWC24ND K3NNB3B Cooling Cooling Cooling Cooling Cooling Cooling 700 1000 Indoor uni t 730X255X...

Page 13: ...WH18ND K3NNC7A GWH18ND K3NND2A GWH18ND K3NND1A Cooling and Heating 1004 973 1450 1400 Indoor unit 790X265X177 Outdoor unit 776X540X320 0 84kg Cooling and Heating 1460 1430 1980 1980 Indoor unit 940X29...

Page 14: ...or unit Air in Air out Outdoor unit Wireless remote control Air in Air out Power cable 7 Cool Dry Heat Set temp Run The pattern in displayer Remote control Front panel Filter Guide louver Wall pipe Bi...

Page 15: ...5 Press this button Sleep On and Sleep Off can be selected After powered on Sleep SLEEP button SLEEP Off is defaulted After the unit is turned off the Sleep function is canceled After Sleep function s...

Page 16: ...could be used for the air conditioners By pressing this key under switch off state you may set the time for auto switch on The TIMER button TIMER range of setting is 0 5 24 hours The characters T ON...

Page 17: ...d and to make ambient comfortable About AUTO RUN 10 Under switch on or switch off state you may hold and key simultaneously to lock and unlock the keypad When locked the display will show the LOCK ico...

Page 18: ...operation should be in its receiving range It should be placed at where is 1m away from the TV set or stereo sound sets If the wireless remote control can not operate normally please take them out aft...

Page 19: ...ur fingers Take down the air filter At the slot of surface panel to open an angle pull the air filter downward and take it out please see the Fig 4 a b To clean the dust adhering to the filters you ca...

Page 20: ...act the dealer Clean and care Check before use Check that whether ground wire is properly connected or not Maintain after use Turn main power off Clean the filter and indoor and outdoor units bodies C...

Page 21: ...lem still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow can be heard during the operation The air conditioner is started when it is run...

Page 22: ...in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged If water leaka...

Page 23: ...lessy splash water or something into unit There is an abnormal heat in power supply cord and power plug Stop running and disconnect the power supply In HEAT mode when the temperature of indoor heat ex...

Page 24: ...lation Important Notices Basic Requirements For Installation Position Install in the following place may cause malfunction If it is unavoidable contact with service center please Place where strong he...

Page 25: ...to the National Criterion 4 The user power must offer the reliable earthing terminal Please don t connect the earthing wire with the following place Tap water pipe Gas pipe Contamination pipe Other pl...

Page 26: ...Space to the wall Air outlet side Space to the floor Above Above Above Above Above Space to the obstruction Air outlet side Space to the wall Air inlet side Above Above e v o b A The dimensions of th...

Page 27: ...rainage pipe 1 For well draining the drain hose should be placed at a downward slant 2 Do not wrench or bend the drain hose or flood its end by water 3 When the long drainage hose passing through indo...

Page 28: ...f the tailings 1 and tailings 2 when routing both the wiring and piping Take out the piping from body case wrap the piping electric wire water pipe with tape and pull them through the piping hole As s...

Page 29: ...ontrol wire Ensure wire has been fixed well Install the handle 5 1 0 10 pa 76cmHg 1 Connect charging hose of manifold valve to charge end of low pressure valve both high low pressure valves must be ti...

Page 30: ...oltage in accordance with the rated voltage marked on the nameplate It may cause electric malfunction or damage the part Is the electric wiring and piping connection installed correctly and securely I...

Page 31: ...tion As for silver ion filter it is invalid when its surface becomes according to the installation instruction Pay special attention to that silver Take out the healthy filter before cleaning and rein...

Page 32: ...dditional refrigerant charging amount on the 1 Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging amount per meter 2 When the length of connection p...

Page 33: ...Diameter of connection pipe mm Indoor unit throttle Outdoor unit throttle Liquid pipe Gas pipe Cooling only cooling and heating g m Cooling only g m Cooling and heating g m 6 9 5 or 12 20 15 20 6 or 9...

Page 34: ...Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com GREE ELECTRIC APPLIANCES INC OF ZHUHAI 66162752...

Reviews: