- 7 -
Notes for installation
Remove
Before removing air conditioner to the other place, you should
contact the seller firstly.
Then it must be done under the direction of the professional
technician. In addition, the charge of this must be paid.
Noise
Electric wiring
Must connect with ground reliably.
The exclusive circuit must be used. But removable socket can’t be used because poor
contact of it can cause over heat or fire.
Don’t pull the power cord strongly.
In fixed circuit, there must be electricity leakage protection switch and leakage current
is less than 30mA.
Connecting method between air conditioners and power cord and interconnecting method
of each individual element with one another should accord with wiring diagram on the unit.
The air conditioner should be installed in accordance with local regulation.
An all-pole disconnection switch having a contact separation of at least 3mm in all poles
should be connected in fixed wiring
Air switch (thermal-magnetic breaker) should be installed in the circuit
If the supply cord is damaged, it must be replaced by the manufacturer o
.
r your dealer
or a qualified person to avoid a hazard.
All the electrical work must be done according to the local wiring regulations.
Shall be installed in the circuit of miniature circuit switch and it has a capacity of 10A (GWA2107BM/R
, GWA2109BM/R, GWA2112BM/ R),16A (GWA2118BM/R ) or 25 A(GWA2124BM/R)
;
Fixed line shall be greater than 1.5mm
2
(GWA2107BM/R, GWA2109BM/R, GWA2112BM/R) and 2.5mm
2
(GWA2118BM/R,GWA2124BM/R);
Install in a location where is firm enough to avoid the enlargement of noise
and vibration.
Don’t put anything in front of the outlet of the unit to avoid increasing
noise.
Be sure that hot air or noise will not inconvenience neighbors.
Please contact the seller as soon as there is strange noise during operation.
Please use the safety support.