HEAT PUMP WATER HEATER (NORTHERN EUROPE) MAINTENANCE
24
UNITS MAINTENANCE
1 ERROR CODE LIST
Code Indication
Error Name
Cause of Error Code
Control Description
E1
Comp High-pressure
protection
Comp High-pressure switch is broken or the wiring is loose.
The water in the tank is not enough.
The installation of tank temp sensor is not correct.
The gas valve and liquid valve are not fully open.
The thermal expansion valve can not work normally.
Press ON/OFF key to clear
E3
Comp Low- pressure
protection
Comp Low-pressure switch is broken or the wiring is loose.
The system has leaked.
The fans stop running or reverse.
Press ON/OFF key to clear
E4
Comp Discharge temp
protection
The resistance of temperature sensor is not correct.
The thermal expansion valve is blocked.
The system has leaked.
Mainboard of outdoor unit is damaged.
Press ON/OFF key to clear
E5
Comp overload protection
AC contactor is damaged.
The compressor wiring is not correct.
The voltage is not normal.
Overcurrent test board is damaged.
The refrigerant of the system is excessive.
Press ON/OFF key to clear
E8
Fan 1 overload protection
Mainboard of outdoor unit is damaged.
The wire connecting the wiring terminals of the mainboard
breaks.
Press ON/OFF key to clear
b8
Fan 2 overload protection
Mainboard of outdoor unit is damaged.
The wire connecting the wiring terminals of the mainboard
breaks.
Press ON/OFF key to clear
F3
Defrost temp sensor failure
The plug on temperature sensor is not correctly connected to the
socket on mainboard.
The resistance of temperature sensor is not correct.
Auto resume
F5
Discharge temp sensor error
The plug on temperature sensor is not correctly connected to the
socket on mainboard.
The resistance of temperature sensor is not correct.
Auto resume
F7
Outdoor ambient temp sensor
failure
The plug on temperature sensor is not correctly connected to the
socket on mainboard.
The resistance of temperature sensor is not correct.
Auto resume
EC
Communication malfunction
The communication line of the unit is not connected.
The communication line is not through.
The communication line of the unit is not connected correctly.
The two ends of communication line are not mounted with
magnetic ring.
The outdoor unit is not electrically powered.
Auto resume
Summary of Contents for GRS-S16/Na-M
Page 1: ...Heat Pump Water Heater Northern Europe Service Manual GREE ELECTRIC APPLIANCES INC OF ZHUHAI ...
Page 3: ...GREE COMMERCIAL AIR CONDITIONERS HEAT PUMP WATER HEATER NORTHERN EUROPE 1 PRODUCT ...
Page 9: ...GREE COMMERCIAL AIR CONDITIONERS HEAT PUMP WATER HEATER NORTHERN EUROPE 7 CONTROL ...
Page 11: ...HEAT PUMP WATER HEATER NORTHERN EUROPE INSTALLATION 9 ...
Page 19: ...HEAT PUMP WATER HEATER NORTHERN EUROPE INSTALLATION 17 INSTALLATION ...
Page 25: ...HEAT PUMP WATER HEATER NORTHERN EUROPE MAINTENANCE 23 MAINTENANCE ...
Page 28: ...HEAT PUMP WATER HEATER NORTHERN EUROPE MAINTENANCE 26 3 Comp Discharge Temp Protection E4 ...
Page 29: ...HEAT PUMP WATER HEATER NORTHERN EUROPE MAINTENANCE 27 4 Comp Overload Protection E5 ...