Air-to-water Heat Pump
31
(3) GRS-CQ12Pd/NaB-K(I), GRS-CQ14Pd/NaB-K(I), GRS-CQ16Pd/NaB-K(I),GRS-CQ12Pd/
NaB-M(I), GRS-CQ14Pd/NaB-M(I), GRS-CQ16Pd/NaB-M(I)
AC_L N
PUMP1
PUMP2
RUN
HEAT3-L
HEAT1-L
HEAT2-L
ERR
2V1_OFF
2V1_ON
2V2_OFF
2V2_ON
3V1_OFF
3V1_ON
T-SENSOR 1
DOOR-C
OVC-HEAT3
OVC-HEAT1
OVC-HEAT2
IN-SW
COM-MANUAL
COM-OUT
TR-OUT1
TR-OUT2
CN30
CN31
TR-IN
T-SENSOR 2
T-SENSOR 3
T-SENSOR 4
T-SENSOR 5
LED1
LED2
LED3
T-SENSOR 6
Other _OFF
Other _ON
Silk screen
Location
Specification
AC-L
-
live wire of power supply
N
-
Neutral wire of power supply
PUMP1
X13
live wire of indoor water pump
PUMP2
X14
live wire of solar water pump
RUN
X15
running indicator
HEAT3-L
X16
e-heater of water tank
HEAT1-L
X17
e-heater of indoor unit 1
HEAT2-L
X18
e-heater of indoor unit 2
ERR
X19
error indicator
2V1_OFF
X5
Electric magnetic 2-way valve1 is normally closed.
2V1_ON
X6
Electric magnetic 2-way valve1 is normally open.
2V2_OFF
X7
Electric magnetic 2-way valve2 is normally closed.
2V2_ON
X8
Electric magnetic 2-way valve2 is normally open.
3V1_OFF
X9
Electric magnetic 3-way valve1 is normally closed.
3V1_ON
X10
Electric magnetic 3-way valve1 is normally open.
Other _OFF
X11
Other auxiliary is normally closed.
Other _ON
X12
Other auxiliary is normally open.
T-SENSOR1
CN10
terminal of temperature sensor1