Sunshade board
Wall
Wooden frame
Rubber plate
Support
4
Horizontal line
Horizontal line
Drain water:
To get the maximum cooling efficiency, the air conditioner is designed to splash the condensation water on the
condenser coil.
To the cooling only unit,
If the splashing sound annoys you, you can provide an outside drain by using the follo
-wing procedure, which
may however cause a small loss of performance.
1. Slide out the chassis from the cabinet.
2. Remove the rubber plug from the body base plate.
3. Install the drain pan to the corner of the cabinet with 2 screws.
4. Connect the drain hose to the outlet on the drain pan bottom.
5. Slide the chassis into its original place in the cabinet.
Installation procedure:
1) Remove the sticker from the front panel.
2) Put the unit into the installation hole.
When installing the unit, it should be slanted
down to the back to avoid the enlargement of
noise or vibration. (Slant between 6-10mm.
)
(
Shown at right figure.)
The installation place should be strong enough
to avoid the enlargement of noise or vibration.
3) Fill up sews in the cabinet with sponge or foam.
Installation assistance:
Use iron support
The installation hole should be strong enough to
support the air conditioner. If it cannot, iron sup-
port has to be used outdoors.
Iron support should be fixed on the building (Shown
at right figure.)
Use sunshade board
Air conditioner should avoid anything to be dropped
into it and avoid direct sunshine. If there is no cover
on it, you should contact the seller for installing
the sunshade board. When installing the sunshade
board, don’t let it block the air inlet at the side grille.