39
Service Manual
Installation and Maintenance
centrifugal louver
nut
Procedure
Step
motor
screws
electric box assembly
8.Remove centrifugal louver
9.Remove pressing wire board
10.Remove motor
11.Remove electric box assembly
Pull out the power cord, wiring of liquid
level switch, compressor wiring connect to
mainboard, unscrew screws fixing electric
box to remove electric box assembly.
Remove the motor wire connect to
mainboard and ground wire connect to
evaporator side plate, unscrew 3 screws
fixing motor to remove motor.
Extrude the two sides of pressing wire
board, then pull the pressing wire board
outwards.
Remove nuts and washer fixing louver of
motor axle, along the motor axle direction
to pull out louver.
pressing wire board