background image

18

i-Feel LCD Remote Control  

The remote acts as a separate thermostat for enhanced comfort. The mini thermostat in the remote 

control can sense its surrounding temperature and transmit the signal back to the unit. The unit will 

cool the room until the desired temperature is met at the location of the remote. Maximum transmission 

distance of remote from unit is 8 m (26 ft).

 Programmable Digital Thermostat 

For precise comfort control. Select the exact desired temperature for maximum comfort.

 24 Hour Programmable Clock Timer 

While in OFF mode enables user to set a specific time for the unit to turn on. When in ON mode, enables 

user to set a specific time for unit to turn off.

 3 Speed Fan & Auto Fan 

Allows more settings for maximum comfort. Auto fan automatically sets the fan speed based on the 

current room temperature and thermostat setting

Evaporative Dehumidifier (Dry Mode) 

Reduces and evaporates unwanted moisture without extra cooling.

Sleep Mode 

Automatically increases the set temperature 2° after the first hour and another 2° after the second hour. 

This feature limits compressor usage and conserves energy.

Energy Saver Mode 

Automatically shuts off both compressor and fan when desired temperature is reached, to conserve 

energy.

Loss of Power Protection with Auto Restart 

Remembers all settings when power is interrupted. As soon as power is restored, the A/C will operate in 

the mode, temperature and settings prior to power loss.

Gold Shield

 

Anti-corrosion coating prevents condenser fin corrosion.

NOTE:

 The default temperature reading on the display is degree Fahrenheit (°F). To change the display to degree Celsius 

(°C), press the Mode and Temp Decrease buttons together and hold for 3 seconds when the remote is turned off. Repeat 
the process to change back to degree Fahrenheit (°F). This cool-only air conditioner was not designed for freezing outdoor 
conditions. 

Do not use in freezing outdoor conditions

.

OPERATING INSTRUCTIONS

Features of Your Window Air Conditioner

Summary of Contents for G17-14ESCWAC1

Page 1: ...numbers below for your records Model Serial Date Purchased Please read the entire manual carefully to ensure proper operation of the product To find an electronic version of this manual please visit w...

Page 2: ...LLATION INSTRUCTIONS 5 17 OPERATING INSTRUCTIONS 18 21 CLEANING MAINTENANCE 22 23 BEFORE YOU CALL 24 26 WARRANTY 27 TABLE OF CONTENTS NOTICE Pictures within this manual are for reference only Please r...

Page 3: ...not disassemble or modify the unit Do not operate with wet hands Do not clean with water that may run inside the units electrical parts This may cause failure of the machine or electric shock Do not p...

Page 4: ...er cord must be replaced if it fails to reset when either the TEST button is pushed or it cannot be reset Please contact Customer Service If the power cord is damaged then it cannot be repaired It MUS...

Page 5: ...ion of Installation Location Installing the unit in the following places can be dangerous and may cause malfunction 1 Areas with strong heat sources vapors flammable or explosive gas sulfated gas or v...

Page 6: ...just for this attach a piece of wood not included to the window sill Wood Piece Width 5 1 cm 2 Length Long enough to fit inside the window frame Thickness To determine the thickness place a piece of w...

Page 7: ...4 Supporter 2 Type E screw 4 Fixing bracket for window 2 Type F screw 2 Type B screw 2 Sponge Upper guide rail Level bar Scissors Pencil Measuring tape Screwdriver Sealing strip with adhesive 2 R1 Sea...

Page 8: ...n Remove 2 Screws from the Control Cover Set aside you will need later during installation Grasp the lower corners of the Front Frame while pressing in on the sides with your fingertips Pull out to re...

Page 9: ...the other person pulls out Main Unit Note Set aside the Grounding Screw in a safe location You will need it later during the installation 4 5 Remove 1 Grounding Screw from side of Outer Case Pull the...

Page 10: ...Upper Guide Rail onto the outer case of the air conditioner unit Upper guide rail may be attached on some units Note For safety all four screws must be SECURELY fastened Hold Frame and extend Flexibl...

Page 11: ...for the appearance INSTALLATION INSTRUCTIONS 9 10 Attach Side Rails to Outer Case using 6 Type A Screws Slide the upper and lower ends of the Flexible Screen Frame into the Upper and Lower Guide Rail...

Page 12: ...nstall the air conditioner onto the window sill it is recommended to use 2 PEOPLE Place the Outer Case with Flexible Panels on the sill with the Lower Guide Rail against the back edge Center the unit...

Page 13: ...ype E Bolts w Nuts 2 for each support type E screw supporter outer case Can be moved vertically to adjust the gradient of outer case 3 Note Ensure placement of V Supports will bear the weight of windo...

Page 14: ...ot holes before inserting the screws Screw Type C Screw Type C To install the fixed bracket attach the bracket to the window side sash with one Type B Screw This prevents broken glass or damage to the...

Page 15: ...NSTALLED CORRECTLY TO ENSURE PROPER GROUND Slide the Main Unit slowly into the Outer Case by the Base Pan Make sure the unit is firmly seated Note Do NOT push on the controls styrofoam air discharge h...

Page 16: ...r to the actual product for the appearance 21 22 A Attach the Front Frame to the Outer Case by inserting the tabs into slots on the top of Outer Case B Push bottom of Front Frame in until secure Repla...

Page 17: ...on into a rectangular shape to match the width as measured in figure 10 B Remove adhesive from back of Foam Insulation Stick the installation evenly on the flexible screen Cover the flexible screen co...

Page 18: ...and evaporates unwanted moisture without extra cooling Sleep Mode Automatically increases the set temperature 2 after the first hour and another 2 after the second hour This feature limits compressor...

Page 19: ...increments by 0 5 hours OPERATING INSTRUCTIONS Function Control Display DESCRIPTION FUNCTION Auto Fan Mode In this mode fan speed will automatically adjust to provide optimum comfort with the set temp...

Page 20: ...e in COOL DRY and ENERGY SAVER mode to maintain the most comfortable temperature Timer Button Press this button to initiate AUTO ON AUTO OFF timer Press this button twice to cancel auto timer i Feel B...

Page 21: ...to the user s preference Adjust the air frame up or down to direct the air flow according to the user s preference OPERATING INSTRUCTIONS Air Flow Adjustment NOTICE This picture is for reference only...

Page 22: ...ot of dust in the operation environment then clean more frequently Do not touch the metal fins in the air conditioner when removing the filter To clean panel surface wipe with a soft dry cloth Check t...

Page 23: ...Control 1 Press the back side of remote control marked with OPEN as shown in the figure and then push out the BATTERY COVER of battery box along the arrow direction 2 Replace two AAA 1 5V dry batterie...

Page 24: ...igerant is passing through the evaporator Pinging or Droplet Sounds When droplets of water hit the condenser during normal operation it may cause pinging or droplet sounds WARNING If the below errors...

Page 25: ...Codes appear please call Customer Service IF THESE SOLUTIONS FAIL PLEASE CALL 1 866 658 0466 FOR GREE CUSTOMER SERVICE BEFORE YOU CALL MALFUNCTION CODE SOLUTION F1 Please contact Customer Service F2 F...

Page 26: ...t to a higher temperature Room is not cooling no ice on back of unit Air restricted due to dirty air filter Remove filter s and clean Temperature is set too high Turn temperature setting down Air louv...

Page 27: ...Damage caused by replacement of house fuses or resetting circuit breakers Damage caused by repairs or alterations Damage caused after delivery Labor or other costs incurred for diagnosing repairing r...

Page 28: ...28 Gree Customer Service Hours 9am 5pm CST Monday Friday Phone 1 866 658 0466 Email customerservice greeproducts com Website www greeproducts com M110516 14ECWAC...