background image

9

Window 
Sill

Window 
Sash

Screws

Frame Locking Brackets (2)

Left

Right

To install the 

Window Sill & Sash Seal

, cut the 

seal to fit the length of the window. Peel off the 
backing, and attach to window sash and window 
sill. 

Place the air conditioner on the sill with the 

Lower 

Guide Rail

 against the back edge. Center the unit, 

and close the window securely behind the 

Upper 

Guide Rail

. The unit should be slightly tilted to the 

outside. Use a level: about 1/3 bubble will show 
correct slant.

To install the fixed bracket, attach the bracket to the 
window side sash with one 

Type B Screw

. This 

prevents broken glass or damage to the windows. 

Front View

Side View

Vinyl 

Window

Wooden 

Window

 

NOTE:  

Top Rail and sliding panels at each side are offset to provide the proper pitch to the 

rear of .8 cm (5/16”). This is necessary for proper condensed water utilization and drainage. If 

you are not using the side panels for any reason, this pitch to the rear must be maintained.

5

7

6

8

Extend the left and right 

Flexible Screens

 to the 

window sashes. Attach 

3 Type B Screws 

in holes in 

the upper panel. Install the 

Frame Locking Brackets

 

between the bottom of the 

Flexible Screen

 and the 

window sill, attach with 

2 Type B Screws

.

Window Sill & 
Sash Seal  
(With Adhesive)

 Note: 

In order to prevent the window 

sill from splitting drive the pilot holes before 
inserting the screws.

 Note: 

To install the air conditioner onto 

the window sill, it is recommended to use 2 
PEOPLE.

INSTALLATION INSTRUCTIONS

NOTICE:

 

This picture is for reference only.  Please refer to the actual product for the appearance.

BACK

FRONT

Upper Guide 
Rail

Lower Guide 
Rail

Window Frame

Horizontal or inclined about 3°

Summary of Contents for G17-12ESCWAC1

Page 1: ...Serial Date Purchased G17 12ESCWAC1 Window Air Conditioner Please read the entire manual carefully to ensure proper operation of the product To find an electronic version of this manual please visit w...

Page 2: ...LLATION INSTRUCTIONS 5 10 OPERATING INSTRUCTIONS 11 14 CLEANING MAINTENANCE 15 16 BEFORE YOU CALL 17 19 WARRANTY 20 TABLE OF CONTENTS NOTICE Pictures within this manual are for reference only Please r...

Page 3: ...not disassemble or modify the unit Do not operate with wet hands Do not clean with water that may run inside the units electrical parts This may cause failure of the machine or electric shock Do not p...

Page 4: ...er cord must be replaced if it fails to reset when either the TEST button is pushed or it cannot be reset Please contact Customer Service If the power cord is damaged then it cannot be repaired It MUS...

Page 5: ...ion of Installation Location Installing the unit in the following places can be dangerous and may cause malfunction 1 Areas with strong heat sources vapors flammable or explosive gas sulfated gas or v...

Page 6: ...it and won t affect others The window should be able to withstand the weight of the unit Select a window where noise and outflow air emitted by unit will not affect others Select a window out of reach...

Page 7: ...Flexible Screen Panel Seal 2 Flexible Screen 2 Upper Guide Rail Window Unit Window Sill And Sash Seal With Adhesive 2 Flathead screwdriver Foam Top Gasket Without Adhesive Top Mounting Rail Seal Strip...

Page 8: ...exible Screens ensure that the sides marked LEFT and RIGHT are installed into the left and right side of the unit A Hold Frame with one hand while extending Flexible Screen with other hand Slide edge...

Page 9: ...re offset to provide the proper pitch to the rear of 8 cm 5 16 This is necessary for proper condensed water utilization and drainage If you are not using the side panels for any reason this pitch to t...

Page 10: ...re 10 length Locate the Foam Insulation from the packaging Cut the insulation into a rectangular shape to match the width as measured in figure 10 Remove adhesive from back of Foam Insulation Stick th...

Page 11: ...and evaporates unwanted moisture without extra cooling Sleep Mode Automatically increases the set temperature 2 after the first hour and another 2 after the second hour This feature limits compressor...

Page 12: ...increments by 0 5 hours OPERATING INSTRUCTIONS Function Control Display DESCRIPTION FUNCTION Auto Fan Mode In this mode fan speed will automatically adjust to provide optimum comfort with the set temp...

Page 13: ...able in COOL DRY and ENERGY SAVER mode to maintain the most comfortable temperature Timer Button Press this button to initiate AUTO ON AUTO OFF timer Press this button twice to cancel auto timer i Fee...

Page 14: ...to the user s preference Adjust the air frame up or down to direct the air flow according to the user s preference OPERATING INSTRUCTIONS Air Flow Adjustment NOTICE This picture is for reference only...

Page 15: ...ot of dust in the operation environment then clean more frequently Do not touch the metal fins in the air conditioner when removing the filter To clean panel surface wipe with a soft dry cloth Check t...

Page 16: ...Control 1 Press the back side of remote control marked with OPEN as shown in the figure and then push out the BATTERY COVER of battery box along the arrow direction 2 Replace two AAA 1 5V dry batterie...

Page 17: ...igerant is passing through the evaporator Pinging or Droplet Sounds When droplets of water hit the condenser during normal operation it may cause pinging or droplet sounds WARNING If the below errors...

Page 18: ...Codes appear please call Customer Service IF THESE SOLUTIONS FAIL PLEASE CALL 1 866 658 0466 FOR GREE CUSTOMER SERVICE BEFORE YOU CALL MALFUNCTION CODE SOLUTION F1 Please contact Customer Service F2 F...

Page 19: ...t to a higher temperature Room is not cooling no ice on back of unit Air restricted due to dirty air filter Remove filter s and clean Temperature is set too high Turn temperature setting down Air louv...

Page 20: ...Damage caused by replacement of house fuses or resetting circuit breakers Damage caused by repairs or alterations Damage caused after delivery Labor or other costs incurred for diagnosing repairing r...

Page 21: ...21 Gree Customer Service Hours 9am 5pm CST Monday Friday Phone 1 866 658 0466 Email customerservice greeproducts com Website www greeproducts com M110516 12ECWAC...