background image

User Notice

This appliance is intended to be used by expert or trained users in shops, in light industry and 

on farms, or for commercial or household use by lay persons.

Installing the unit in the following places may cause malfunction. If it is unavoidable,please 

consult the local dealer:

1.The place with strong heat sources,vapors, flammable or explosive gas,or volatile objects 

spread in the air.

2.The place with high-frequency devices (such as welding machine,medical equipment).
3.The place near coast area.
4.The place with oil or fumes in the air.
5.The place with sulfureted gas.
6.Other places with special circumstances.
7.Do not use the unit in the immediate surroundings of a laundry a bath a shower or a swimming 

pool.

DISPOSAL

: This marking indicates that this product should not be disposed 

with other household wastes throughout the EU. To prevent possible harm to the 
environment or human health from uncontrolled waste disposal, recycle it responsibly to 
promote the sustainable reuse of material resources. To return your used device, please 
use the return and collection systems or contact the retailer where the product was 
purchased. They can take this product for environmental safe recycling. 

This appliance can be used by children aged from 8 years 

and above and persons with reduced physical,  sensory or 

mental capabilities or lack of experience and knowledge if they 

have been given supervision or instruction concerning use 

of the appliance in a safe way and understand the hazards 

involved.Children shall not play with the appliance. Cleaning 

and user maintenance shall not be made by children without 

supervision.

Summary of Contents for FP-51XD-E

Page 1: ...ng commercial or household air conditioners Please read this Owner s Manual carefully before operation and retain it for future reference If you have lost the Owner s Manual please contact the local a...

Page 2: ...ing pool DISPOSAL This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontr...

Page 3: ...4 1 Schematic diagram of installation spaces 5 4 2 Selection of the installation location of the FCU 5 4 3 Important notice 6 4 4 Dimension of ceiling opening and location of the hoisting screw 6 4 5...

Page 4: ...he unit may be damaged and may cause electric shock or fire Keep combustible spray away from the units more than 1m It can cause a fire or explosion Don t attempt to repair the air conditioner by your...

Page 5: ...ap water pipe Gas pipe Contamination pipe Other places that professional personnel consider them unreliable 5 The appliance shall be installed in accordance with national wiring regulations 6 Installa...

Page 6: ...i heat wind function In order to ensure comfort of the users under circumstances such as the cool mode just starts or the unit runs cool mode under hot water temperature the fan will stop running to p...

Page 7: ...6 Make sure that there are enough space for care and maintenance Make sure that the height between the FCU and ground is above 2500mm 7 When installing the steeve bolt check if the installation place...

Page 8: ...that is not special nominated by Gree would not deal with on time by the inconvenience of the business contact 4 4 Dimension of ceiling opening and location of the hoisting screw Fig 3 Installation D...

Page 9: ...Hanging bolt M10 Fig 5 Fig 6 1 Install special nut A then special nut B onto the hanging bolt Fig 7 2 Raise the body and mount its hooks onto the hanging bolt between the special nuts Fig 7 3 Turn sp...

Page 10: ...in pipe height raise it up to 15 400 mm or less from the ceiling within a range of 6 150mm from the body T he raised height over this range will cause leakage Fig 9 4 7 Installation connecting the pip...

Page 11: ...e flare nut During the installation both the torque wrench and the spanner should be used and the moment of torque should be within 90 N M Besides a secure connection should be guaranteed 2 Both the t...

Page 12: ...oard 3 Use pliers to bend the solid wire to form a loop suitable for the terminal screw 4 Shape the loop wire properly place it on the terminal board and tighten securely with the terminal screw by us...

Page 13: ...ith the four bolts spring washers and washers No gap between ceiling and grille around entire periphery Fig 16 4 11 Wireless unit connection wire wiring 1 Connect the connector in accordance with part...

Page 14: ...r is missing operate as shown below 2 On stopping you can press the AUTO button on cover NO II until it is on AUTO mode 3 The air conditioner select from COOL HEAT DRY FAN modes automatically 4 On ope...

Page 15: ...on the components burn out Is the unit safely grounded Risk of electric leakage Is wiring size according to specifications The unit may malfunction the components burn out Is something blocking the ai...

Page 16: ...and valve The temp of water is higher or lower NOTE If trouble still exists after checking the above items please contact service center The following are not troubles Trouble Cause The unit does not...

Page 17: ...d for installation indoor The environmental temperature is from 5 C to 43 C water working temperature is from 7 C to 60 C The A weighted sound pressure level is below 70dB The temperature exchange eff...

Page 18: ...GREE ELECTRIC APPLIANCES INC OF ZHUHAI Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com...

Reviews: