background image

Vertical Exposed Fan Coil Unit

1

Safety notices (please be sure to abide )

 WARNING

: If not abide strictly, it may cause severe damage to the unit or the people.

 

NOTE

: If not abide strictly, it may cause slight or medium damage to the unit or the people.

 This sign indicates that the operation must be prohibited. Improper operation may cause severe 

damage or death to people.

 This sign indicates that the items must be observed. Improper operation may cause damage to 

people or property.

WARNING

Please perform installation in 

accordance with this manual 

and read it carefully prior to 
startup and service.

Installation should be done 

by sales agents or qualified 

servicemen. Do not do it 
personally, as incorrect 

installation would lead to water 
leakage, electrocution, fire 

hazards etc.

Before installation, check 

for power supply and see if 
it complies with that on the 

nameplate. Besides, check for 

safety of the power supply.

This unit should be grounded 
and there should be grounding 

lines for the power socket so 

as to prevent electrocution. Do 
not connect the grounding lines 

to the gas lines, water lines, 

lightning rod or telephone 
lines.

Specialized 

Fittings

Specialized components 
and parts should be used 

for installation; otherwise it 
would lead to water leakage, 
electrocution, fire hazards etc.

Specialized

Size of the power lines should 
be large enough. Power lines 

and other electric connection 
lines should be replaced by 
specialized cables.

When wiring of power lines is 
finished, remember to install a 

electric box to prevent safety 
accidents.

When installation is finished, 

check for connection of drain 

lines, water lines and electric 

lines, as incorrect connection 

would lead to water leakage, 
electrocution, fire hazards etc.

Do not start or stop the unit by 

drawing out or plugging in the 
power plug.

Do not let the children play 

with this unit.

Do not operate this unit with 
wet hands.

Do not clean this unit until the 

unit is turn off and the power 
supply is cut off, otherwise it 
would lead to electrocution or 

personal injury.

Summary of Contents for FP-102LM/D-K

Page 1: ...al Exposed Fan Coil Unit Owner s Manual Original Instructions Commercial Air Conditioners Models FP 22LM D K FP 34LM D K FP 51LM D K FP 68LM D K FP 85LM D K FP 102LM D K FP 119LM D K FP 136LM D K FP 1...

Page 2: ...ble for their safety Children should be supervised to ensure that they do not play with the appliance 2 This product has gone through strict inspection and operational test before leaving the factory...

Page 3: ...tenance space 8 2 5 Installation of inlet and outlet pipes 8 2 6 Installation of the drain hose 9 2 7 Installation of the water valve 10 2 8 Electric wiring 12 3 Thermostat guide 13 3 1 Thermostat pan...

Page 4: ...ly This unit should be grounded and there should be grounding lines for the power socket so as to prevent electrocution Do not connect the grounding lines to the gas lines water lines lightning rod or...

Page 5: ...eaving water lines condensate lines and valves should be thermal insulated so as to prevent from dewing in summer Do not repair this unit by yourself as incorrect repair would lead to electrocution or...

Page 6: ...s and electric connection lines should be secure enough Terminals also should be tightly fastened The connection line should not suffer external forces For the unit equipped with the wired controller...

Page 7: ...or a swimming pool DISPOSAL This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health f...

Page 8: ...ested to be not higher than 65 C normally 60 C otherwise it would lead to corrosion of copper tubes or abnormal noise 2 The suggested working environment temperature for cooling ranges 16 40 C and ran...

Page 9: ...the the table below Suspension hole Suspension hole Unit mm Model FP 22LM D K 555 390 FP 34LM D K FP 51LM D K 710 FP 68LM D K FP 85LM D K FP 102LM D K 1010 FP 119LM D K FP 136LM D K FP 170LM D K 1433...

Page 10: ...tal way Open the cover Loosen screws Lift the decorated panels on left or right side 1cm above After Before Remove it in Suspension hole Suspension hole a horizontal way Hang the unit by fiting the ho...

Page 11: ...723 FP 102LM D K 1350 680 585 230 1023 FP 119LM D K 1350 680 585 230 1023 FP 136LM D K 1350 680 585 230 1023 FP 170LM D K 1773 680 585 230 1446 FP 204LM D K 1773 680 585 230 1446 2 4 Installation and...

Page 12: ...n left or right side 1cm above After Before Remove it in a horizontal way Outlet pipe Inlet pipe Drain pipe Wire the electric box 2 6 Installation of the drain hose 2 6 1 Precautions for the drain hos...

Page 13: ...t one end of the water pipe to the water inlet of the unit and then connect the other end to water valve During installation both the torque wrench and ordinary wrench should be used For the former th...

Page 14: ...tor Insulation sleeve Water pipe Put the connection line through the PVC pipe and then bind them with the insulation sleeve Connection line of the actuator PVC pipe Insulation sleeve Water pipe Never...

Page 15: ...the magnetic or electric trip off functions so as for shortcutting and overloading protection 6 The unit should be grounded reliably The yellow green line is the grounding line Do not put it into othe...

Page 16: ...WN 3 2 Technical parameters Item Description Supply voltage AC85 265V 50 60Hz Temperature setting 16 30 C Operation temperature 0 50 C Humidity Relative humidity 5 95 no condensate Load current 2A res...

Page 17: ...se the thermostat 3 3 1 ON OFF As shown in Figure 1 press ON OFF to start or stop the unit If it is on the screen provides the operation mode temperature and fan speed among which only temperature app...

Page 18: ...ithout any operation in 5 seconds Figure 3 Celsius Fahrenheit 3 3 5 Timer 1 The unit is timed to start or stop ranging from 0 5 to 24 hours 2 As shown in the Figure 4 after starting the unit to keep p...

Page 19: ...operating in 1 hour and another 1 C in another 1 hour The set temperature will rise 2 C at most and be steady at 28 C with the function automatically disabled In the heating mode using the sleep funct...

Page 20: ...ecision of 1 F 09 Heating temperature set in the energy saving mode Adjustable range 16 C 30 C a precision of 0 5 C 30 C by default When the temperature unit is Fahrenheit the adjustment range of the...

Page 21: ...be adjusted to the limit value As shown in the Figure 8 on the parameter setting page press MODE to switch the option number to 02 UP or DOWN is provided to allow a switch between ON and OFF Figure 8...

Page 22: ...ng when the indoor ambient temperature reaches the specific temperature point As shown in the Figure 11 on the parameter setting page pressing MODE activates a switch to the option number 05 UP or DOW...

Page 23: ...ure 13 on the parameter setting page press MODE to switch the option number to 07 UP or DOWN is provided to a switch between 1 2 and 3 the three ranges Figure 13 8 Cooling temperature set in the energ...

Page 24: ...justment range of the temperature is 61 F 86 F with a precision of 1 F Figure 15 10 Ambient temperature display If the user enables the indoor ambient temperature display after the start up of the uni...

Page 25: ...temperature The user is allowed to adjust the set temperature Figure 18 No Code Description 1 F5 Indoor ambient temperature sensor failure 3 5 Failure handling The product maintenance is performed by...

Page 26: ...ter at the air inlet or outlet It would lead to poor cooling capacity 4 2 Trial run 1 Preparation before trial run y y Do not power the unit on until all installation has been finished y y Control and...

Page 27: ...er There are foreign matters at the return inlet and air outlet Clear foreign matters The duct resistance exceeds the design value Lower the duct resistance or reselect the unit 4 The cooling or heati...

Page 28: ...GREE ELECTRIC APPLIANCES INC OF ZHUHAI Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail global cn gree com www gree com...

Reviews: