Fengyun Series
Operation Process / Photoes
Disassemble Motor
Use a screwdriver to
unscrew
the
two
screws fixing the motor
clamp and then remove the motor clamp.
Unscrew
the
3 holding
screw
s
on the bearing
cover
and remove the motor.
(refer to Figure 7-1
1,7-12
)
Figure 7-1
1
clamp
screws
Disassemble Cross Flow Fan
T
ake out the bearing holder at the left, and remove the
cross flow fan.
(refer to Figure 7-1
3
)
Bearing Holder
Figure 7-1
2
Figure 7-1
3
screws
screw
motor
Cross Flow Fan
Cross Flow Fan