background image

CASSET TE B SERIES

 OWNERS MANUAL - INDOOR UNIT

 |

 15

• Press FUNCTION under on state of the unit till the 

unit enters the WiFi setting interface, the temperature 
area will display the WiFi status. Press “ ” or “ ” 
button to turn on WiFi(“ON” is displayed) or turn off 
WiFi (“OFF” is displayed), and then press “SWING/
ENTER”button to confirm it.

NOTE:

1.  WiFi can be only be reset or turned off by the 

buttons on the wired controller, not the remote 
controller.

2.  WiFi networking performance is related to the 

distance between the wired controller and the 
router and the obstacles between them. During 
the installation process, the distance between the 
wired controller and the router should be as close 
as possible, and the obstacles should be as little 
as possible.

3.  If the WiFi signal is weak, use a WiFi repeater or 

more powerful router.

4.  The specific situation depends on the actual 

installation.

3.18 Other Functions

(1). Lock-out
• If there are no malfunctions, during “ON” or “OFF” 

state of the unit, press   and   at the same time for 5s till 
the wired controller enters the Lock-out function. In this 
case. LCD displays  . After that, repress these two 
buttons at the same time for 5s to disable this function.

• Under the Lock-out state, any other button press won’t 

get any response.

(2). Memory
• Memory switchover: Under the “OFF” state of the unit, 

press Mode and   at the same time for 5s to switch 
memory states between memory on and memory 
off. When this function is activated, Memory will be 
displayed. If this function is not set, the unit will be 
under the “OFF” state after power failure and then 
power recovery.

• Memory recovery: If this function has been set for 

the wired controller, the wired controller after power 
failure will resume its original running state upon 
power recovery.

• Memory contents: ON/OFF, Mode, set temperature, 

set fan speed and Lock-out function.

(3). Selection of the Temperature Sensor
• Under OFF state of the unit, press both “FUNCTION” and 

“TIMER” for five seconds to go to the commissioning 
status. Under this status, adjust the display in the 

temperature display area to “00” through the button 

“MODE”, and then adjust the option of the temperature 

sensor in the timer display area through the button 

or   

.

1.  Indoor ambient temperature is sensed at the return 

air inlet (01 in the timer display area).

2.  Indoor ambient temperature is the sensed at the 

wired controller (02 in the timer display area).

3.  Select the temperature sensor at the return air inlet 

under the cooling, dry and fan modes while select 

the temperature sensor at the wired controller 

under the heating and auto modes. (03 in the timer 

display area)

4.  Select the temperature sensor at the wired controller 

under the cooling, dry and fan modes, and select the 

temperature sensor at the return air inlet under the 

heating mode and auto modes (04 displayed in the 

timer display area).

(4). Selection of the Fan Speed 

• Under OFF state of the unit, press both the buttons 

“FUNCTION” and “TIMER” for five seconds to go to the 

commissioning status, and then adjust the display in 

the temperature display area to 01 through the button 

“MODE” and adjust the setting of the fan speed, which 

comes to two options. 

01: Three low fan speeds; 02: Three high fan speeds .

NOTE:

• After connected with indoor unit, if the type of 

ambient temperature sensor has not been manually 

set, the wired controller will select the ambient 

temperature sensor according to the model of 

connected IDU; if it connects to cassette type IDU, 

duct type IDU, floor ceiling type IDU, ceiling type 

IDU, it will adopt 

 

3

, otherwise it will adopt 

 

1

. If the 

type of ambient temperature sensor is set manually, 

the wired controller will be subject to the manual 

setting, and will not set according to automatic IDU 

model selection.

• After setting, press “SWING/ENTER” to make a 

confirmation and quit this setting status

• Pressing the button “ON/OFF” also can quit this 

commissioning status but the set data won’t be 

memorized

• Under the commissioning status, if there are no new 

inputs for 20 seconds, it will go back to the previous 

state without memorizing the current data.

WIRED CONTROLLER (Continued)

Summary of Contents for CAS12HP230V1BC

Page 1: ...LS CAT NO GREE_CASSETTE B_OWNERS_11102022 Thank you for choosing our product Please read this Owner s Manual carefully before operation and retain it for future reference To download an electric versi...

Page 2: ...other GREE installed products worldwide has gone into your unit Please read this owner s manual carefully before operation and retain it for future reference TABLE OF CONTENTS Nomenclature 3 Safety Pr...

Page 3: ...l Electrical Rating 230V 208 230V 1PH 60Hz Style Color Designation Product Type O Outdoor Units C Indoor Cassette D Indoor Slim Duct F Indoor Floor Ceiling Model Type HP Heat Pump Capacity 12 12 000 B...

Page 4: ...hanced installation reliability or operation NOTE Your actual air conditioning heating system and related devices may differ from the images shown in this manual WARNING This appliance is not intended...

Page 5: ...g be careful not to splash water on the unit Doing this may cause electric shock or damage to unit Do not use or place any flammable combustible or noxious substance next to the unit In the event of a...

Page 6: ...ired Controller 6 Remote Controller 7 Big handle 8 Liquid Pipe 9 Gas pipe 10 Drainage pipe 11 Front Board Indoor unit Outdoor unit 2 3 4 7 5 6 1 8 9 10 11 Air inlet Air outlet Fig 1 DISCLAIMER Not all...

Page 7: ...it It then adjusts airflow and temperature accordingly for ultimate personal comfort ADJUSTABLE AIRFLOW The Cassette B Series system has a four directional airflow for maximum comfort The indoor unit...

Page 8: ...ections and system parameters are stored in non volatile memory These parameters are retained during a power failure When power is returned the Cassette B Series system will automatically return to th...

Page 9: ...when I DEMAND function is set Display when WiFi function is set Lock out status display when lock out function is set Display when up and down swing function is set Icon of follower controller it will...

Page 10: ...er the lock state in which case any other buttons won t respond Repress them for 5s to quit this state Under OFF state the Celsius and Fahrenheit scales can be switched by pressing MODE and for 5s Und...

Page 11: ...Cooling Dry Fan or Heating mode the temperature setting range is 61 F 86 F 16o C 30o C IntheAutomode thesettingtemperatureisunadjustable 3 4 Fan Setting Under the ON State of the unit each time you p...

Page 12: ...ion Swing setting is shown as Fia 9 NOTE 1 Use the Swing setting procedure to initiate Sleep Turbo or X fan 2 Oncethesettingiscompleted press SWING ENTER to initiate another setting or it will automat...

Page 13: ...indoor unit will be automatically evaporated to avoid mildew In the Cooling or Dry mode press FUNCTION till the unit enters the X fan setting interface and then press SWING ENTER to activate When the...

Page 14: ...Demand setting interface Press SWING ENTER to confirm the setting I Demand off When the I Demand function is activated press FUNCTION to enter the I Demand setting interface After that press SWING ENT...

Page 15: ...e seconds to go to the commissioning status Under this status adjust the display in the temperature display area to 00 through the button MODE and then adjust the option of the temperature sensor in t...

Page 16: ...SERIES OWNERS MANUAL INDOOR UNIT 16 OPERATION OF REMOTE CONTROLLER Buttons on remote controller Introduction for icons on display screen Remote lock out DISCLAIMER All functions are not available for...

Page 17: ...ate in a fan only mode no heating or cooling and all indicators will be off When all indicators are off press FAN button to adjust fan speed Press button to adjust fan blowing angle When selecting HEA...

Page 18: ...down at maximum angle Select and fan modulation will stop at that fixed position Horizontal louver will stop at the fixed position Select will not modulate but blow at a fixed angle Hold button more...

Page 19: ...on the remote controller When set the remote controller will send the detected ambient temperature to the controller and the unit will automatically adjust the indoor temperature according to the det...

Page 20: ...ither Sleep function and 46 F 8 C heating function can t operate at the same time If 46 F 8 C heating function has been set under heat mode pressing the SLEEP button will cancel 46 F 8 C heating funct...

Page 21: ...e unit is installed in a room where the air is extremely contaminated As a yardstick for yourself consider cleaning the filter once a half year If dirt becomes impossible to clean change the air filte...

Page 22: ...the HEAT mode In order to prevent cold air from blowing out it may take several minutes before the fan starts This is normal Air conditioner isn t coming on Power failure Wait until power recovery Lo...

Page 23: ...s clippings and other debris can stick to coil fins and make the unit work up to 15 harder 5 Rearrange the room Furniture that obstructs the airflow needs to be removed or rearranged accordingly 6 Try...

Page 24: ..._____________________ Serial No ___________________________________ Outdoor Model No _____________________________ Serial No ___________________________________ Owner Name ____________________________...

Page 25: ...U S CONTACT INFORMATION TRADEWINDS LLC E mail info twciimate com Contractor Support 888 850 7928 I Mon Fri 8 AM 5 PM EST G R E E C O M F O R T C O M...

Reviews: