background image

90236 GE50-94 REV A 8-3-12 

ELECTRICAL CONNECTION

 

 

A 15 AMP, 120 Volt, 60 Hz circuit with a properly grounded outlet is required. The unit comes standard with 6 feet (1.8 m) 
three wire cord, exiting from the rear of the fireplace. Plan the installation to avoid the use of an extension cord. Preferably, 
the fireplace will be on a dedicated circuit as other appliances on the same circuit may cause the circuit breaker to trip or 
the fuse to blow when the heater is in operation. 
 
 

CLEANING TRIM

 

 

Clean the glass trim using a soft cloth and household glass cleaner and buff with a clean soft cloth if streaking occurs. 
 

MAINTENANCE

 

 

WARNING: ALWAYS UNPLUG THE CORD BEFORE MOVING OR SERVICING. 

DO NOT IMMERSE HEATER IN WATER! 

  Always turn OFF the heater and disconnect the cord from the electrical outlet before cleaning your heater. 

  Light accumulated dust may be removed from the heater with a soft cloth or vacuum cleaner. 

  Wipe the exterior surfaces of the heater occasionally with a slightly damp cloth (not dripping wet) using a solution 

of mild detergent and water. Dry the case thoroughly before operating the heater. 

 
Caution:

 Do not allow water to run into the interior of the heater as this could create a fire or electric shock hazard. 

  The fan motor is factory lubricated for life and will not require further lubrication. 

 

Warning: 

Any other servicing needed must be performed by an authorized service representative. Do not attempt to 

service the unit yourself.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for GE-50

Page 1: ...ERVICE MUST BE PERFORMED BY A QUALIFIED SERVICE AGENCY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE PLEASE READ THIS MANUAL BEFORE...

Page 2: ...from outlet 15 Connect to properly grounded outlets only 16 This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the curren...

Page 3: ...nfo 1 Wall Mounting Bracket 1 2 Fire Box with Heater 1 3 Fireplace Front 1 4 Remote Control 1 5 Battery 2 6 Instruction Manual 1 7 Plastic Wall Anchor Plug 6pcs for GE 50 58 8pcs for GE 70 94 8 Screw...

Page 4: ...inal packaging for future transport and or storage Check that all listed parts have been included before discarding any packaging LOCATING YOUR ELECTRIC FIREPLACE Your new electric fireplace may be in...

Page 5: ...s a guide Fig 3 3 If locating the fireplace on existing wall studs or solid wood walls Screws can be inserted at this time and you can proceed to step 6 otherwise continue the steps below for placing...

Page 6: ...e front as pictured Fig 7 Secure the fireplace front with 2 M4 8 screws in the tabs on top of the fire box 9 Connect the backlighting cable at the bottom of the glass to that of the fire box Fig 8 Fig...

Page 7: ...RNING ALWAYS UNPLUG THE CORD BEFORE MOVING OR SERVICING DO NOT IMMERSE HEATER IN WATER Always turn OFF the heater and disconnect the cord from the electrical outlet before cleaning your heater Light a...

Page 8: ...ects by pressing the flame effect button the unit will cycle through each effect HEATER BUTTON Press once turns 750W power on Pilot lights illuminated Press again turns 1500W power on Pilot lights ill...

Page 9: ...trips circuit breaker or blows fuse when turned on Improper circuit rating Ensure unit is plugged into a dedicated 15 amp circuit Too many appliances plugged into the same circuit Unplug other applia...

Reviews: