Great Plains Manufacturing, Inc.
Table of Contents
Index
Adjustments
29
2013-03-25
Table of Contents
Index
403-362M
Coulter Adjustment
The frame-mounted coulters standard on the
YP2425F-2470, YP4025F-1630 and YP4025F-1670 are
configured for “zone” application: 5cm offset from seed
furrow, and
5cm depth, or “2x2”in.
As blades wear, or under unusual field conditions, you
may need to adjust the coulter depth. If the depth is
adjusted, the applicator needs to be adjusted as well.
Coulter Height Adjustment
Refer to Figure 17
1.
Raise the planter. Install transport locks.
2.
Move the planter to a flat level surface. A paved area
is ideal.
3.
At each coulter, measure the raised tool bar height
(“
Bar_Height
”)
.
4.
For a 2.5cm (2in) coulter depth, compute the ideal
raised height
of the disk edge.
Metric:
Inch:
5.
Reset the coulter shank to the new “
Edge_Height
”.
Coulter Applicator Adjustment
Normally, the coulter tine tip
is set to exactly ground
level, although you may set it higher or lower for unusual
conditions. To change the height, loosen the mounting
bolt
and move the applicator weldment up or down.
If you are adjusting the tine height, to ground level, with
the planter raised, use:
Metric (cm):
or, U.S. customary (inches):
Figure 17
Dry Fertilizer Coulter
31109
1
2
4
3
1
2
Edge_Height
Bar_Height
66
–
5
–
=
Edge_Height
Bar_Height
26
–
2.5
–
=
3
4
Tine_Height
Edge_Height
5
+
=
Tine_Height
Edge_Height
2.5
+
=