Section 5: Maintenance & Lubrication
RC4015 & RCM4015 Rotary Cutters 334-300M
9/19/16
Conventional Main Driveline Profile Tubes
Type of Lubrication: Multi-purpose Grease
Quantity = Coat Generously
Figure 5-13
23567
Zerk located through slot in plastic outer tubes
23567
23556
8-10 pumps
Zerk Located through slot in tube
23556
4-5 pumps
2-3 pumps
2-3 pumps
4-6 pumps
Conventional Main Driveline Joints & Shields
Type of Lubrication: Multi-purpose Grease
CV Main Driveline Profile Tubes
With External Grease Point
CV = Constant Velocity
Type of Lubrication: Multi-purpose Grease
Quantity = 8-10 pumps
IMPORTANT:
To extend the life of the constant
velocity joint, the grease zerk for the profile tubes
must be lubricated every 8 hours.
CV Main Driveline Joints
CV = Constant Velocity
Type of Lubrication: Multi-purpose Grease
For instructions on how to access grease zerks shown
in Figure 5-13: See
“Accessing CV Driveline Joints”
•
The constant velocity joint should be greased in a
straight position forcing grease through the passages
and into the cavity. After lubrication, grease should
be visible around the ball joints.
•
Grease fittings located on the u-joints and driveline
shields should be lubricated every 8 Hrs of operation.
IMPORTANT:
To extend the life of the constant
velocity joint, extensive lubrication must be
performed every 8 hours of operation.