background image

Power Hockey Overhead  

Setup & Assembly Instructions  

 

 
 

 

 
 
 
 

20 Providence Pike 

North Smithfield, RI 02896 

800-831-2011 • (f) 401-463-6673 

www.GreatAmericanRec.com 

[email protected] 

Summary of Contents for Power Hockey Overhead

Page 1: ...Power Hockey Overhead Setup Assembly Instructions 20 Providence Pike North Smithfield RI 02896 800 831 2011 f 401 463 6673 www GreatAmericanRec com games greatamericanrec com...

Page 2: ...cover 1 Small Light Bar mount cover 12 1 1 2 x 1 4 20 bolts 4 1 2 x 1 4 20 bolts 4 1 4 nuts 16 1 4 locking washers 4 1 4 washers 8 5 8 8 pan head screws Table Maintenance This is a commercial table an...

Page 3: ...s See figure 1 4 Stand table upright 5 Attach Light Bar as instructed in the next section Front View of Power Hockey Table Figure 1 5 8 8 pan head screw Small Light Bar Mount Cover Locks Puck Drop Acc...

Page 4: ...t Fixture 2 pin connector to matching connector in Light Bar 7 Attach 25 pin harness from light bar to the Score Panel at connector marked INTERFACE NOTE Make sure the notches on the harness face cent...

Page 5: ...time of 5 minutes To change these settings refer the DIP switch setting sheet attached to the inside of the power supply access door see figure 3 In order to change the coins required per game play p...

Page 6: ...L E F T S C O R E S W IT C H C O IN S W IT C H R IG H T S C O R E S W IT C H Power Hockey Wiring Diagram Rev 11 4 98...

Page 7: ...G A R E AT ME RICAN RE CRE AT ION E QU IPME NT INC 110 POWE R S U PPL Y B OX DIAGR AM...

Page 8: ...IT ON OFF ON OFF 11 ON OFF ON OFF 1 COIN 1 CREDIT ON OFF OFF ON 10 ON OFF OFF ON 1 COIN 1 CREDIT ON OFF OFF OFF 09 ON OFF OFF OFF 2 COINS 1 CREDIT OFF ON ON ON 08 OFF ON ON ON 2 COINS 1 CREDIT OFF ON...

Page 9: ...2 3 4 5 6 7 8 End Of Play Score 6 0 0 7 1 0 8 0 1 9 1 1 End Of Play Timer Minutes 6 0 0 9 1 0 12 0 1 15 1 1 Coins Per Play If using a slide mech this is set to one and the slide determines the pricing...

Page 10: ...one coin 1 0 0 0 2 1 0 0 3 0 1 0 4 1 1 0 5 0 0 1 6 1 0 1 7 0 1 1 8 1 1 1 Multiply or Divide Pulses MULTIPLY 0 DIVIDE 1 Denotes Factory Setting Connector Pin Outs Pin 1 is left hand pin facing connecto...

Page 11: ...e AC IN 1 1 2 N C AC IN 1 3 4 Coin 2 Switch AC IN 2 5 6 DC Ground AC IN 2 7 8 DC Ground N C 9 10 Start Switch N U DC Ground 11 12 Left Puck Switch DC Ground 13 14 Right Puck Switch DC Ground 15 16 Coi...

Page 12: ...d unplug the black blower cord very important which is located on the side of the power supply unit 5 Remove all screws around the top outside edge of the table located below the top rails and remove...

Page 13: ...COIN OP TABLES ONLY ESD COIN MECH PRICE CHANGE SHEET...

Reviews: