TROUBLESHOOTING
Problem
Probable Cause
Suggested Remedy
No Machine Function
Machine unplugged
Plug machine into appropriate wall socket
GFCI tripped
Press RESET button on GFCI
No power at outlet
Consult plant electrician
Heat Not Working
Thermostat tripped
Press red thermostat reset button
Heater malfunction
Contact Graymills for more information 1-888-472-9645
Heater coil dirty
Clean heater coil (see Recommended Maintenance)
Red “RESET” Light ON
Machine needs to be reset
Toggle RESET switch
Low solution level
Add cleaning solution
Float sensor or control relay
malfunction
Contact Graymills for more information 1-888-472-9645
Little or No Fluid Flow
Valve shut off
Turn valve fully to the left or right to open valve
Clogged filter
Replace filter cartridge (Part #BIOFL1)
Cracked or broken hose
Inspect and replace hose (See parts list)
Bioremediation No
Longer as Effective
Expired microbes
Add BIO-POUCH to tank solution
If your problem is not listed above or problems persist, please contact Graymills for further assistance. 1-888-472-9645