![Gravely 988001 Service Manual Download Page 34](http://html1.mh-extra.com/html/gravely/988001/988001_service-manual_2258596034.webp)
9 - 34
Pro 200 Walk-Behind Kohler Engine
NOTES: NORMALLY OPEN SWITCHES. MANUALLY ACTIVATED. CONTACT RESISTANCE IS 0.1 - 0.3 OHMS
RESISTANCE.
NOTES: NORMALLY OPEN SWITCH. LARGE CONTACTS ARE 3 TO 5 OHMS RESISTANCE. SMALL
TERMINALS 0.1 TO 0.3 OHMS.
Ignition Switch
Off
Run
Start
Red (B)
12.00
12.00
12.00
Brown (S)
12.00
Pink (A)
12.00
12.00
Red/White (M)
Connected to kill (magneto) circuit to ground
Left and Right Presence Switch
Off
Run
Start
Brown
12.00
White (When activated)
12.00 to ground
Hourmeter
Off
Run
Start
Pink
12.00
12.00
White
12.00
12.00
Solenoid
Off
Run
Start
Triple Red
12.00
12.00
12.00
Red (starter input)
12.00
Brown (input lead)
12.00
Brown and Yellow (output)
12.00
Interlock Module
Off
Run
Start
Red
Connected to engine ground for engine kill
Yellow
12.00
12.00
Brown
12.00
12.00
Summary of Contents for 988001
Page 42: ...9 42 Pro 200 Briggs Stratton 16 HP...
Page 43: ...9 43 Pro 200 Kohler Engine...