GRAUPNER GENIUS PRO 120R for W-Lan Manual Download Page 13

13 / 32

S3084_S3086_S3078_S3085_MP_V1

Settable values in the program

Programmable 

Items

Parameter Values

Default

Motor Type

Sensor only for S3084,S3086,S3078

Hybrid only for S3078,S3086,S3085 Sensor

Select Battery

LiPo / LiFe / NiMH (NiCd)

LiPo

Cut Off Voltage

Disable / Auto / 3.0V ~ 7.5V (Step:0.1V) 

Disable / Auto / 6.0V ~ 23V (Step:0.1V)_S3085

Auto

Power Curve

0 ~ 10

5

Boost Max+TB

Boost                                               Max                                +                                     TB 

Off                                                       X                                                                           X 

ON                                        0 ~ 58 (Hybrid:25)                                             0 ~ 58 (Hybrid:25) 

+TH                                       0 ~ 58 (Hybrid:25)                                             0 ~ 58 (Hybrid:25)

       Off

Boost Min-rpm

0 ~ 64500 (Step: 500 rpm)

5000 rpm

Boost Max-rpm

0 ~ 65000 (Step: 500 rpm)

25000 

rpm

Boost-TH. Limit

TH                                                   Limit 

20%                                       0 ~ 58 (Hybrid:25) 

40%                                       0 ~ 58 (Hybrid:25) 

60%                                       0 ~ 58 (Hybrid:25) 

80%                                       0 ~ 58 (Hybrid:25) 

100%                                     0 ~ 58 (Hybrid:25)

 

 

 

         0

Turbo Delay

0.00 ~ 1.00s (Step: 0.05s)

0.20s

Turbo + Slope

0.00 ~ 1.00s (Step: 0.05s)

0.20s

Turbo -  Slope

0.00 ~ 1.00s (Step: 0.05s)

0.20s

Acceleration

0 ~ 10

5

Start Power

0 ~ 100 (Step: 1%)

0%

Start Curr Limit

Off, 1% ~ 100% (Step: 1%)

Off

Current Limit

Off, 1% ~ 100% (Step: 1%)

Off

Reverse Function

One Way / Two Way / Two Way 2 / Two Way 3

One Way

Reverse Delay

Off / 0.2s / 0.5s / 0.8s / 1.3s / 1.8s / 2.5s

2.5s

M-Reverse Amount 20 ~ 100% (Step: 1%)

100%

Neutral Width

Narrow / Normal / Wide

Wide

Motor Direction

Normal / Reverse

Normal

Brake Response

0% ~ 100% (Step: 1%)

0%

A.B.S. Brake

Off / Weakest / Weak / Normal / Strong / Strongest

Off

Drag Brake

0% ~ 100% (Step: 1%)

0%

Min Brake Amount

0% ~ 100% (Step: 1%)

30%

Mid Brake Amount

0% ~ 100% (Step: 1%)

50%

Mid Brake Location

0% ~ 100% (Step: 1%)

50%

Max Brake Amount

0% ~ 100% (Step: 1%)

100%

Soft Brake

Hard / Soft

Soft

Soft

Brake Freq

1KHz / 2KHz / 5KHz / 8KHz / 16KHz / 32KHz

1KHz

Motor Freq

1KHz / 2KHz / 5KHz / 8KHz / 16KHz / 32KHz

8KHz / 16KHz

5KHz

Drag Freq

1KHz / 2KHz / 5KHz / 8KHz / 16KHz / 32KHz

1KHz

Cut Off Temp

100° ~ 135° (Step: 5) / Disable

135°

Cut Off M-Temp

100° ~ 135° (Step: 5) / Disable

135°

B.E.C. Voltage

6.0 / 7.4V

6.0V

Current Voltage

XX.X

Current Temp

100° ~ 135°

Max Temperature

100° ~ 135°

Motor Temp

100° ~ 135°

Motor Max Temp

100° ~ 135°

Max Current

0 A ~ 999 A 

Motor Pole Num

2 ~ 20 Pole

2 Pole

Gear ratio

2.0 : 1 ~ 15.0 : 1

2.0 : 1

Tire Diameter

40mm ~ 200mm

63mm

Motor-Wiring

A-B-C / C-B-A

A-B-C

Maximum Speed

XXX.X Km/h

Maximum RPM

XXX rpm

Error History

M, T1, T2, S, V, R

Download

All parameters inside the setup card are downloaded to the ESC.

Restore Memory

All setting information inside EEPROM are read via the RAM.

Backup Memory

All setting information inside the RAM are stored at EEPROM

Factory Setting

Change the setting of ESC to default status.

Summary of Contents for GENIUS PRO 120R for W-Lan

Page 1: ...EN No S3084 60R No S3086 120R No S3078 160R No S3085 180R GMGeniusPro Manual C o p y r i g h t G r a u p n e r S J G m b H SpeedcontrollerwithtelemetryandW LANmodule optional...

Page 2: ......

Page 3: ...tion in the model and commissioning 10 Motor connection 11 Setting the throttle travel 12 LED error display 15 LED status display 15 ESC data view in the telemetry menu 15 Programming with HoTT transm...

Page 4: ...nd firmware This product complies with national and European legal require ments To maintain this condition and to ensure safe operation you must read and follow this user manual and the safety notes...

Page 5: ...the speed controller Graupner SJ constantly works on the development of all products we reserve the right to change the item its technology and equip ment Target group The product is not a toy It is n...

Page 6: ...1 8th motors No 7023 7026 Operating voltage 2S LiPo 6 cells NiMH 1 2S LiPo 4 6 cells NiMH 1 2S LiPo 4 6 cells NiMH 2 6S LiPo 6 18 cells NiMH Voltage drop at 20 A each phase 0 026V 0 016V 0 0095V 0 01...

Page 7: ...or instruction by a responsible person Operation and use of radio controlled models needs to be learned If you have never operated a model of this type before start carefully and make yourself familia...

Page 8: ...in connections do not pull the cables Avoid shock and pressure Check if there are damages on the speedcontrollerbodyorcables Damagedorwet evenifre dried esc must not be used anymore Risk of short circ...

Page 9: ...ection use batteries with the same connector system only Do not solder for more than 5 seconds at a time and ensure that there is sufficient cooling to avoid damaging the controller The cables to the...

Page 10: ...roller will immediately switch on when the battery is connected Setup Button The button can only set the throttle level Installation in the model and commissioning Mount the speed controller in the mo...

Page 11: ...to the destruction of the speed controller In the C B A configuration change to C B A in the Motor Wiring menu item in the speed controller to maintain the correct direction of rotation of the motor...

Page 12: ...ect Switch on the controller Once all connecting cables are connected properly the motor generates a short beep to indicate that the power supply is connected Now press the push button for longer than...

Page 13: ...Step 1 100 Neutral Width Narrow Normal Wide Wide Motor Direction Normal Reverse Normal Brake Response 0 100 Step 1 0 A B S Brake Off Weakest Weak Normal Strong Strongest Off Drag Brake 0 100 Step 1 0...

Page 14: ...tor A lower value corre sponds to softer start up of the motor a higher value means some what more power Start power When used as launch control this can greatly simplify starts Power curve Affects pr...

Page 15: ...e position Green LED Red LED Neutral On Off Neutral 0 boost flashes Off Full throttle Off On Full braking On On ESC data view in the telemetry menu Telemetry data display on a Graupner SJ HOTT transmi...

Page 16: ...er Setup Page 6 Min Brake 30 Mid Brake 50 Mid BrakeLoc 50 Max Brake 100 Drag Brake 0 Soft Brake Soft E S C SENSOR User Setup Page 2 Battery LiPo Cut_off V Auto Pwr Curve 5 Acceleration 5 Start power 0...

Page 17: ...nction on the transmitter 2 Boost Max TB OFF All timing is disabled The LED should blink GREEN at neu tral in this mode This is the preferred mode for Stock Racing ON The speed and efficiency of a mot...

Page 18: ...ved to full When a value is entered the turbo is only activated after the throttle is moved to full and the set delay time has elapsed Turbo Slope Set the amount of time it takes to reach turbo speeds...

Page 19: ...the motor and improve the drivability of your vehicle Reverse Func reverse function Reverse function on off One Way Functions forward brake Two Way 1 Functions forward brake reverse Driving in reverse...

Page 20: ...l Reverse Brake Response Adjust the break strength The higher the percent the stronger the brake A B S Brake Here you can set the ABS braking effect Off Weakest Weak Normal Strong Strongest You set AB...

Page 21: ...ontrol the higher the frequency the lower the control Motor Freq Set the motor frequency The lower the frequency the faster the initial acceleration the higher the frequency the softer the acceler ati...

Page 22: ...cuts off Motor CutOff cutoff temperature of the motor You set the maximum temperature of the motor here Disable cutoff not active 100 C 135 C On reaching the maxi mum set temperature the controller cu...

Page 23: ...Page 5 Maximum current Warning threshold for the maximum current of the motor warning threshold adjustable between 25 and 200A Note The warning threshold should never be programmed higher than the max...

Page 24: ...A Warning Time off Repeat Time ALWAYS Signal Tone W MAX CURR 5 3A ESC MOTOR TEMP set warning page 4 Temperature 60 C Warning Time off Repeat Time ALWAYS Signal Tone I MOTOR Temp 29 C ESC WARNING set w...

Page 25: ...mum ESC motor temperature since the device has been switched on mAh used battery capacity is actually not supported A Central and column indicators actual current Right value maximum current since the...

Page 26: ...26 32 S3084_S3086_S3078_S3085_MP_V1...

Page 27: ...lled The drivers are in the software packet HoTT_PC_Software 2 Select COM Port 3 Start the Speed controller program In the Device program group start the Speed controller pro gram Alternatively select...

Page 28: ...he application will then attempt to download the current firmware over the Internet Immediately after clicking on the button the bar starts to become green Switch on the controller at the switch befor...

Page 29: ...60R No S3086 120R No S3078 160R No S3085 180R Graupner SJ declares that the product is conform to EU norms EMV 2004 108 EC EN 301 489 1 V1 9 2 EN 301 489 17 V2 1 1 EN 62479 2010 LVD 2006 95 EC EN 6095...

Page 30: ...your own interests protect it from dust dirt and moisture Warranty The Graupner Henriettenstrassee 96 73230 Kirchheim Teck grants from the date of purchase of this product for a period of 24 months Th...

Page 31: ...31 32 S3084_S3086_S3078_S3085_MP_V1 Notes...

Page 32: ......

Reviews: