![GRASS VALLEY TRINIX NXT - Installation Manual Download Page 227](http://html.mh-extra.com/html/grass-valley/trinix-nxt/trinix-nxt_installation-manual_2257813227.webp)
Trinix NXT — Installation and Service Manual
227
Section
11
Trinix Asymmetrical Power
Supply Configurations
Introduction
The Trinix Asymmetrical routers use external power supply modules,
which reside in a 1 RU power supply frame. Each of these frames can house
up to four power supply modules. The power supply modules are moni-
tored by means of I
2
C links.
The number of power supply frames, power supply modules, and I
2
C links
can vary depending on the model of the asymmetrical router that is used
and the redundancy configuration. This section provides the configuration
guidelines for the interface, connectivity, and monitoring of the power
supply modules.
The External Power Supply Frame
The Lineage Compact Power Line Shelf (see
) is the current
power supply frame that is used for the Trinix Asymmetrical routers.
Figure 135. Lineage Power Supply Frame
The Lineage power supply frame supports up to four power supply mod-
ules. The power supply frame sets the output voltage of each power supply
module to 48 VDC.
Summary of Contents for TRINIX NXT -
Page 10: ...10 Trinix NXT Installation and Service Manual Preface ...
Page 26: ...26 Trinix NXT Installation and Service Manual Regulatory Notices ...
Page 30: ...30 Trinix NXT Installation and Service Manual ESD Protection ...
Page 120: ...120 Trinix NXT Installation and Service Manual Section 9 Planning Guide ...
Page 284: ...284 Trinix NXT Installation and Service Manual Section 12 Broadlinx Installation ...
Page 336: ...336 Trinix NXT Installation and Service Manual Section 14 Broadlinx Console Commands ...
Page 370: ...370 Trinix NXT Installation and Service Manual Section 16 Protected Paths ...
Page 436: ...436 Trinix NXT Installation and Service Manual Appendix 22 Trinix Frame Slot Maps ...
Page 440: ...440 Trinix NXT Installation and Service Manual Appendix 23 Expanded System Sizes ...