19
NV9605
User’s Guide
Checkbox Options
The checkbox options section is just below the panel options section, enclosed in the same
region:
A check in the box enables the option. Clearing the checkbox disables the option.
By default, all the check box options are clear.
The following items are the checkbox options:
•
User-Programmable ID.
Allows the Panel ID to be changed locally at the control panel (in menu mode).
•
Source Master Default.
Makes a control-level source the
controlling
device (or master device) by default.
Otherwise, the destination is the master, by default. (The option is specifically for use
with NVISION series machine control routers.)
“Source is master” is used for duplication, or broadcast routing, on a machine control
level. “Destination is master” is for machine-to-machine editing. If you do not select the
“source master default” option, you can place a ‘Source is Master’ button on the panel.
Note:
a ‘Source is Master’ button is a toggle that reverses the direction of data
routing for devices used in data level (machine control) takes.
•
Hold preset default.
When this checkbox is checked, the panel powers up in “hold mode.” Otherwise it
powers up with hold mode off.
Hold mode, under limited X-Y mode, also allows a user to route a source to multiple
destinations simultaneously.
Hold mode also allows breakaway level patterns to remain selected after a take.
•
Hide sources not configured on this panel.
Causes the names of source devices that are not presently configured for this particular
panel to be effectively hidden. When another panel changes the source to one not
configured for this panel, this panel displays asterisks instead.
•
Use asterisk for breakaway.
If you check this box, the software places asterisks in the 8th character position of
source names that contribute to breakaway. If you clear this box, the software leaves
source names unchanged.
Default Name
Set
System Name
A list of “name sets” appears in the drop-down menu. The
name sets can be defined under the System Management
pane of NV9000-SE Utilities. Choose ‘System Name’ in this
list if you do not want, or do not care about, alternate device
names. Do
not
choose ‘System Name’ if you are configuring
any ‘Name Set Toggle’ buttons.