63
Misc. Topics
Chapter 7 provides the following:
Summary
Setting the Timeout Value
The NV9616 has panel options that use a timeout value. You can set the timeout value in
NV9000-SE Utilities. Choose the ‘SysParams’ table from the ‘Tables’ folder under the ‘Views’
navigation pane. Click ‘Add’ and enter a timeout value as shown:
Fig. 7-1: SysParams Table (in NV9000-SE Utilities)
The name of the parameter must be exactly as you see it here. The timeout value
(expressed in seconds) must be a non-negative value. A suggested value is 120 seconds
(two minutes) or more. The default timeout value is 30 seconds.
The timeout value applies to all panels in your system controller’s panel and router
network.
If you do not add a timeout value to the ‘SysParams’ table, the timeout period will be
the default of 30 seconds.